Question about Ford Cars & Trucks

1 Answer

2010 Ford F-150 crew cab power rear slider window

Rear slider will not close. Want advice and schematics to test the switch (combined with sun roof) and circuit.

Posted by Paul Eslinger on

Ad

1 Answer

Gil Shultz

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Ford Master
  • 3,388 Answers

Ford makes many vehicles with a sunroof and since I do not know you I will take a guess, try these llinks:

How to Repair an Ailing Sunroof

Ford Fusion Power Sunroof

Ford 150 FX4 Power Sunroof

Things to check when Power Rear Sliding Window doesn work Ford F150 Forum

Posted on May 30, 2016

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

O1 expedition , why the sun roof will not work


Did you use a voltmeter an check for B+ voltage to the switch ?
  • The roof opening panel does not open or close
  • Roof opening panel adjustment.
  • Battery junction box (BJB) Circuit Breaker 601 (30A).
  • Circuitry.
  • Roof opening panel switch.
  • Roof opening panel motor assembly.
  • Roof opening panel lifter assemblies.
  • Go To Pinpoint Test E .

Jul 25, 2018 | Cars & Trucks

1 Answer

Sun roof won't close 2004 Ford Explorer


The roof opening panel is an electronically operated panel that can be opened or closed by the roof opening panel switch. Actuating the switch in either a forward or rearward motion supplies a ground to the roof opening panel motor. The vent and soft-stop functions are controlled by the roof opening panel motor. These positions are obtained when an internal motor cam opens the roof position switch, removing the ground from the switch. The roof opening panel has an express open feature activated when the switch is pressed momentarily. The roof opening panel is closed by continuous activation of the switch until the sunroof stops movement. This function is controlled by the roof opening panel motor.

Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Opening shield
  • Roof panel frame
  • Opening shield guide feet
  • Central junction box (CJB) fuses:
    • 2 (20A)
    • 29 (5A)
  • Battery junction box (BJB) fuse 1 (60A)
  • Accessory delay relay
  • Roof opening panel control switch
  • Circuitry
  • Roof opening panel motor

  • The roof opening panel does not open or close
  • Central junction box (CJB) fuse:
    • 2 (20A).
    • 29 (5A).
  • Battery junction box (BJB) fuse 1 (60A).
  • Circuitry.
  • Roof opening panel control switch.
  • Roof opening panel motor.
  • Go To Pinpoint Test E .

Do the power windows and power locks work ?

E6 CHECK VOLTAGE TO THE ROOF OPENING PANEL MOTOR - CIRCUITS 400 (LB/BK) AND 1173 (BN/OG)
  • Key in OFF position.
  • Disconnect: Roof Opening Panel Motor C920.
  • Key in ON position.
  • NOTE: Activate accessory delay relay for this check.
  • Measure the voltage between roof opening panel motor C920-4, circuit 400 (LB/BK), and ground; and between roof opening panel motor C920-7, circuit 1173 (BN/OG), and ground.
  • Are the voltages greater than 10 volts?
Yes
GO to E7 .

No
REPAIR circuit 400 (LB/BK) or circuit 1173 (BN/OG). TEST the system for normal operation. If you can't do electrical testing , there is a manual way to close it .
Roof Opening Panel Manual Operation
  1. Remove the overhead console. For additional information, refer to Overhead Console in this section.
  1. Insert a hex-head screwdriver in the center of the manual drive slot to depress the release pin. Rotate the screwdriver clockwise until the roof opening panel is closed.

Jan 13, 2017 | 2004 Ford Explorer

1 Answer

2000 Buick regal sunroof won't close any suggestions


Could be due to failure of the sun roof switch, the limit switch module, the sun roof actuator, the sunroof module or the 30A PWR WINDOWS PWR SUN ROOF CIRCUIT BREAKER in the I/P fuse block.

Sep 18, 2016 | 2000 Buick Regal

1 Answer

Sunroof will not close. Was working fine earlier today


The roof opening panel assembly uses an integrated motor and module to operate the roof opening panel. The roof opening panel motor and module are installed new as an assembly. The roof opening panel is an electronically operated glass panel that can be opened or closed by the roof opening panel switch. Actuating the switch in either a forward or rearward motion supplies a ground to the roof opening panel motor/module. The soft-stop function is controlled by the roof opening panel motor/module. The roof opening panel has 3 modes of operation, manual mode, express open and tilt. The express open feature is activated when the switch is pressed momentarily. The tilt feature is activated when the tilt switch is depressed. These functions are controlled by the roof opening panel motor/module.
Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Roof opening panel frame
  • Roof opening panel drain hoses
  • Roof opening panel lifter assemblies
  • Roof opening panel water trough
  • Roof opening panel rear trough guides
  • Roof opening panel air deflector assembly
  • Roof opening panel seal
  • Roof opening panel shield
  • Smart junction box (SJB) circuit breaker 47 (30A)
  • Circuitry
  • Accessory delay relay
  • Roof opening panel switch
  • The roof opening panel does not open or close - one direction only
  • Circuitry
  • Roof opening panel switch
  • Roof opening panel motor assembly
  • Go To Pinpoint Test E .
PINPOINT TEST E: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSE Test Step Result / Action to Take E1 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES FOR OBSTRUCTIONS OR DAMAGE
  • Check the roof opening panel lifter assemblies for obstructions and damage.
  • Are the roof opening panel lifter assemblies OK?
Yes
GO to E2 .

No
REMOVE all obstructions and REPAIR any damage. If lifter assemblies cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel Frame in this section. TEST the system for normal operation. E2 CHECK THE ROOF OPENING PANEL WATER TROUGH AND REAR TROUGH GUIDES
  • Check the water roof opening panel water trough and rear trough guides for any loose obstructions.
  • Are the roof opening panel water trough and rear trough guides installed securely and free from obstructions?
Yes
GO to E3 .

No
REMOVE all obstructions from the roof opening panel water trough and install securely. SECURE the rear trough guides or INSTALL new roof opening panel rear trough guides if damaged. REFER to Roof Opening Panel Rear Trough Guide in this section. TEST the system for normal operation. E3 VERIFY THE ROOF OPENING PANEL ADJUSTMENT
  • Verify the roof opening panel is adjusted correctly.
  • Is the roof opening panel adjusted correctly?
Yes
GO to E4 .

No
ADJUST the roof opening panel. REFER to Roof Opening Panel Alignment - Horizontal Adjustment and Roof Opening Panel Alignment - Height Adjustment in this section. TEST the system for normal operation. E4 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR INITIALIZATION
    NOTE: The roof opening panel motor initialization procedure must be done when repairs are carried out on any part of the roof opening panel assembly, including whenever the roof opening panel motor/module has been removed from the roof opening panel assembly, a new roof opening panel motor/module has been installed or when a new roof opening panel assembly has been installed. Refer to Roof Opening Panel Motor Initialization in this section.
  • Carry out the Roof Opening Panel Motor Initialization procedure. Refer to Roof Opening Panel Motor Initialization in this section.
  • If the concern still present?
Yes
GO to E5 .

No
The system is operating correctly. The roof opening panel motor/module was uninitialized. E5 CHECK THE POWER WINDOWS
  • Key in ON position.
  • Verify the power windows operate.
  • Do the power windows operate?
Yes
GO to E6 .

No
REFER to Section 501-11 to diagnose the accessory delay relay circuit. E6 CHECK THE ROOF OPENING PANEL SWITCH
  • Carry out the roof opening panel switch component test. Refer to Wiring Diagrams Cell 149 for schematic and connector information.
  • Did the roof opening panel switch pass the component test?
Yes
GO to E7 .

No
INSTALL a new roof opening panel switch. TEST the system for normal operation. E7 CHECK CIRCUIT CBP47 (GN/BU) FOR VOLTAGE
  • Key in OFF position.
  • Disconnect: Roof Opening Panel Motor/Module C922.
  • Key in ON position.
  • Measure the voltage between roof opening panel motor/module C922-4, circuit CBP47 (GN/BU), harness side and ground.
    s7j~tr~en~file=a0083978.gif~gen~ref.gif
  • Is the voltage greater than 9 volts but less than 16 volts?
Yes
GO to E8 .

No
VERIFY the smart junction box (SJB) circuit breaker 47 (30A) is OK. If OK, REPAIR the circuit. TEST the system for normal operation. E8 CHECK CIRCUIT GD143 (BK/VT) FOR AN OPEN
  • Key in OFF position.
  • Measure the resistance between roof opening panel motor/module C922-3, circuit GD143 (BK/VT), harness side and ground.
    s7j~tr~en~file=a0084276.gif~gen~ref.gif
  • Is the resistance less than 5 ohms?
Yes
GO to E9 .

No
REPAIR the circuit. TEST the system for normal operation. E9 CHECK CIRCUITS CPR37 (YE/GY), CPR39 (VT/WH) AND CPR40 (YE/OG) FOR AN OPEN
  • Disconnect: Roof Opening Panel Switch C930.
  • Measure the resistance between the roof opening panel motor/module C922-1, circuit CPR40 (YE/OG), harness side and roof opening panel switch C930-8, circuit CPR40 (YE/OG), harness side. Measure the resistance between roof opening panel motor/module C922-2, circuit CPR39 (VT/WH), harness side and roof opening panel switch C930-11, circuit CPR39 (VT/WH), harness side. Measure the resistance between roof opening panel motor/module C922-5, circuit CPR37 (YE/GY), harness side and roof opening panel switch C930-14, circuit CPR37 (YE/GY), harness side.
    s7j~tr~en~file=n0054600.gif~gen~ref.gif
  • Are the resistances less than 5 ohms?
Yes
GO to E10 .

No
REPAIR the circuit. TEST the system for normal operation. E10 CHECK FOR CORRECT ROOF OPENING PANEL MOTOR/MODULE OPERATION
  • Disconnect the roof opening panel motor/module connectors.
  • Check for:
    • corrosion.
    • pushed-out pins.
  • Connect all roof opening panel motor/module connectors and make sure they seat correctly.
  • Operate the system and verify that the concern is still present.
  • Is the concern still present?
Yes
CHECK the jumper harness between the vehicle harness and the roof opening panel for open or shorted circuits. If the jumper harness is not OK, INSTALL a new jumper harness between the vehicle harness to the roof opening panel motor/module. Otherwise, INSTALL a new roof opening panel module/motor. REFER to Roof Opening Panel Motor in this section. TEST the system for normal operation.

No
The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.

May 08, 2016 | 2008 Ford Expedition El

1 Answer

Moonroof wont close all the way


Do you know how to test automotive electrical circuit's with a DVOM - digital volt ohm meter ? When adjusting the moon roof did you see any switches ? sunroof limit switch
Measure the reference voltage of the sunroof limit switch soft stop signal circuit at the sunroof control harness connector to a good ground.
Does the reference voltage measure near the specified value?
4.5-5.5 V
Notice: Do not open the sunroof glass past the full open soft stop position. Doing so may damage the sunroof assembly and or the roof top.
Connect a jumper wire to the sunroof limit switch soft stop signal circuit at the sunroof control module harness to a good ground.
Turn ON the ignition, with the engine OFF.
Using the sunroof switch, operate the sunroof system, not to exceed the full open soft stop position.
Does the system operate as requested?

Do you know what a wiring diagram is ? Free one's here
http://www.bbbind.com/free_tsb.html Enter vehicle info. year ,make ,model an engine size . Under system click body & accessories ,then under subsystem click on sun roof . Click the search button then the blue link . See the control module , motor an the two switches ? One is probably miss adjusted . or bad !

Power Sunroof System Components
The power sunroof system consists of the following components:
• Sunroof control module
• Sunroof motor with the limit switches
• Sunroof switch
• Sunroof glass-spoiler type, with glass sliding above roof
• Sunshade
• Rail and track assembly upon which the sunroof glass rides
• Power sunroof system circuit breaker: PWR WDO 25 A
• Ground: G204

Sunroof Limit Switches
The sunroof limit switches track the position of the sunroof glass through two limit switches:
• Soft Stop limit switch through the sunroof limit switch soft stop signal circuit
• Vent Stop limit switch through the sunroof limit switch range signal circuit
The sunroof control module monitors the limit switches and based on the input combinations, determines the position of the sunroof glass. As a sunroof limit switch closes, the 5 volt reference will be shorted to the sunroof limit switch low reference circuit, pulling the 5 volt reference to 0 volts.
The sunroof control module monitors both sunroof switch input requests and based on the sunroof limit switch input combinations, will control an output to the sunroof motor, to drive the sunroof glass to the requested position.

Sunroof Motor
The sunroof has a bi-directional motor. When the motor is not operating both circuits are grounded. When the motor drives the sunroof glass in the direction from the closed to vent or vent to open position, the following occurs:
• Voltage is supplied to the sunroof motor open circuit.
• Ground is maintained to the sunroof motor close circuit.
When the motor drives the sunroof in the direction from the open to vent or vent to closed position, the following occurs:
• Voltage is supplied to the sunroof motor close circuit.
• Ground is maintained to the sunroof motor open circuit.
The sunroof control module is equipped with a timer circuit which stops the operation of the sunroof motor after 8 seconds.

Dec 23, 2017 | 2003 Pontiac Sunfire

1 Answer

Sunroof does not close, how do you manually close the sunroof 2003 Kia Sorento


I can't tell you how to close it manually but I think you should do a couple of other things first.
Remember I am not there to help you and I am only trying to help so be kind with your rating of me if my ideas fail,
Check the fuses first. It may say sun roof on the diagram on the cover of thefuse box which is probably under the dash.
If it does not say sun roof i don't know what else it would be called.
Just check all the fuses one by one if the diagram doesn't help. You will be looking for a burnt fuse. there is a wire on the inside that will look melted oe burnt. replace it with the same amp type that came out of it. Keep checking the rest of the fuses even if you find a bad one. Sometimes more then one blows at the sametime. If all the fuses are good or your replaced a bad one and it still doesn't work then I will have you check the switch. Yo7u can take the switch out and pull the two wires off remembering where they went. There may be three wires but only pull two off at a time. You want to touch two together using different combinations until the roof closes or trys to move. if this works then it is your switch. Be sure to have the key on in the on position while testing this. it will not shock you so don't worry. If the ends of the switch wires are coverd then you will need to get a wire that you can bend and put in to the two ends conncting them to make a good circuit. The must touch metal to metal. If all the combinations fail then it may be a bad motor after all.
So these are my ideas, I hope I got lucky and saved you tons of cash, Raz

Apr 19, 2010 | 2003 Kia Sorento

2 Answers

Sun Roof Problam


maby sum white lithium grease spray the track or a debris is stuck in the path

Aug 22, 2009 | 1999 Cadillac Seville

3 Answers

Can't open a 2002 Mercedes c230 kompressor sun roof


It's typically the motors or the special drive tubes that it uses. If you here a clicking noise then the sunroof became to tight and ruined the motor gears. You can actually switch the two motors, one is for the shades and needs less power then the other motor. They are identical, switch them. Nex make sure they are very tight to the 3 mounting bolts, there is a rubber washer bushing that wears out and alloys the motor to flex too much, causing the gear mis-alignment and gear grinding. This works great I do it all the time.

Apr 11, 2009 | 2002 Mercedes-Benz C-Class

1 Answer

Chrysler concorde sun roof stuck open!!


Check the fuses to start with. If they are fine it could be a broken switch or a burnt electrical motor. If the closing mechanism has broken and bound up it could keep the window from closing. With the car in accessory mode or ON -whichever allows the windows to open - hit the close switch and listen closely. if a click of the motor can be heard it is a mechanical issue - if not it is electrical.

Feb 26, 2009 | 1998 Chrysler Concorde

1 Answer

Power sun roof


It may be a circuit breaker.My windows and door locks stopped working,even after checking all fuses and replacing Main Driver side door switch! Found three circuit breakers that you can reset with a paper clip or small screwdriver. They were black with an aluminum cover on top. They don't come out easily,just insert the pin on each one.

Jul 27, 2008 | 1992 Pontiac Grand Prix

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

241 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ford Experts

Marvin
Marvin

Level 3 Expert

85239 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22485 Answers

gerry bissi

Level 3 Expert

4388 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides