SOURCE: My 2002 Sebring keeps blowing the starter fuse?
Mine is doing the same thing. We are getting ready to replace the starter. Hopefully that is the problem. I'll let you know how it turns out.
SOURCE: 98 grand cherokee asd relay blowing fuse
The fuse it doing it's job, you have a short ( Wire that is connected to a ground, that draws too much power )
If you have an electrical schematic ( Repair manual ) find out which wires are connected to that fuse and check them for any chaffing, cuts, unnesassary twists, or corrosion.
If you have a ohm-meter, isolate the system ( by disconnecting the fuse, and other connections. Then check for any resistance on wires that should not be connected ( because you disconnected them ) by having one Lead on the wire's connector and the other meter-lead on your car's frame. A good wire will not have continuity if it is isolated.
SOURCE: my 1991 toyota 4runner keeps blowing the efi fuse
Check the EFI main relay, the circuit opening relay, and the fuel pump relay. Inside the fuel pump relay there is a switch controlled by a coil. During start, the fuel pump gets full power for a couple of seconds to build up pressure. Once pressure is good, the fuel pump relay is supposed to switch (via the coil) the fuel pump to reduced power. If the coil in the relay is bad, the reduced power setting is not available and the fuel pump will run at full power all the time. At this heavy current draw, it won't be long until the EFI fuse blows. This would also give more pressure than is necessary to the cold start fuel injector which runs on a timer. This extra pressure during the time that the cold start injector is operating may be the reason the engine is flooding with fuel.
SOURCE: 1990 toyota pickup 3.0 v6,engine
This is an unfortunatly common problem with this vehicle, if my hypothesis is correct. Try this: disconnect the wiring connector going to the fuel tank, under the bed. Replace the fuse and crank the engine. If the fuse does not blow, then the power wire going to the fuel tank sending unit is shorted out to ground. I change about 15-20 fuel sending units a year for this exact same issue. Replace the fuel tank sending unit if the fuse does not blow. When you get it out, you will see the cause of the short, rust at the connection on top of the sending unit. Hope this helps.