Anonymous Posted on Sep 18, 2014

Blower motor relay 2007 outlander

Replaced blower motor was bad now new don't work and it is good motor what may be wrong

3 Related Answers

roniecon

Ronny Bennett Sr.

  • 6988 Answers
  • Posted on Jul 03, 2010

SOURCE: my blower motor isn't working properly. I hav

The motor ,or the fan selector switch,and connector most likely are the problem,check the fan,it could be at fault,or the switch,and connector,as for the floorboard being wet,it is most likely the drain for the evaporator is stopped up,look directly below where the ac lines go in the firewall(in the car from under the hood)the drain will be there,blow it out with air pressure,like a air tank,and blow gun.Water will pour out like a water fall if you get it clear.If this was helpful,please rate,and thank you.

Ad

Anonymous

  • 672 Answers
  • Posted on Dec 11, 2010

SOURCE: front blower motor will not

This may be a faulty Blower motor resistor, usually mounted inside the blower motor air box, or defective blower motor. There is no single Relay for the blower motor.

skychief2001

Stephen

  • 21873 Answers
  • Posted on Feb 25, 2013

SOURCE: installed new blower motor. bearing shelled in old one. new motor won't blow. tested . it's good don't have power to moter. fuses good relay good. isthere a circuit breaker in wiring for b

I don't have a diagram for a 2008. On 2005 models the blower motor relay gets power from a 30amp fuse.
When the blower switch is in the high position the resistor is bypassed and power flows directly to the motor. The motor is grounded to the car.
The fan relay also gets power from a 7.5amp fuse and is controlled by the HVAC control on the dash.
Do you have power into and out of the relay?

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

New blower motor and resistor. Fan still not working/ only occasionaly

Usually, when the resistor goes bad it will still work at high speed! check the connector to make sure is making a good connection!
0helpful
2answers

What would cause my 2007 Mitsubishi, Outlanders blower motor to stop working? Fuses good.

Have you checked your blower relay in the under-hood relay / fuse block? I found a photo that may help you identify which it is. If the other relays in the block are the same type (all markings the same), you can swap one out for it to see if that fixes it before moving in deeper.

c4a11ce8-5acd-4e07-bf82-f173225eb0d9.jpg
0helpful
1answer

Where is the blower motor relay on a 2007 trailblazer?

Should be in the underhood fuse/relay panel. These dont often fail.
0helpful
1answer

Blower motor only works on low and medium on 2007 dodge nitro

You replaced the resistor and WHAT relay? The blower motor circuit on a 2007 Dodge Nitro does not use a relay.

The blower resistor gets it's power from the A/C - heater control unit.

If you check for voltage at the blower motor resistor connector (Key on, relay disconnected), the DARK BLUE/GREY wire should be hot when the control switch is on HIGH. The DARK BLUE/VIOLET wire should be hot with the switch in the MEDIUM 2 position.The DARK BLUE/ORANGE wire should be hot with the switch in the MEDIUM 1 position. The DARK BLUE/BROWN wire should be hot with the switch on LOW.

If any of these are not as stated above, then you either have a bad A/C - heater control unit, or faulty wiring between the control unit and the resistor.
0helpful
1answer

2003 mitsubishi outlander heater fan doesn't work, how might I fix it?

either bad blower motor resistor (least expensive fix to atempt) , or blower motor bad or electrical circuits to motor
0helpful
1answer

MY 2002 CRV BLOWER IS NOT WORKING

check the fuse, blower motor relay, and the blower resistor, the one i think is bad, i don't think is something wrong with your blower motor, good luck.
3helpful
1answer

Fan for ac/heat does not work on lower settings

The blower motor resistor is bad.Replacing that should fix the issue.In addition it is possible that the blower motor may have caused the resistor to go bad. If that is the case then the blower motor should be replaced as well.
0helpful
2answers

G6 GT2007 Blower fan does not work at all. All

check relay HVAC relay.if all is good.blower motor is bad or HVAC control switch is bad.
0helpful
1answer

Electric windows and tempeture on dash are not working

IF ALL WINDOWS ARE NOT WORKING IT LOOKS LIKE.THE POWER WINDOW CIRCUIT BREAKER IS BLOWN.CHECK THE HEATER AND AC IGNITION FUSE.MAKE SURE POWER IS AT THE SWITCH.IF ALL IS GOOD.CHECK BLOWER MOTOR FUSE AND RELAY.IF THEY ARE GOOD.HOT WIRE BLOWER MOTOR IF IT WORK YOU HAVE A BAD BLOWER MOTOR SWITCH AND RESISTOR.IF BLOWER MOTOR DONT WORK.REPLACE BLOWER MOTOR.
Not finding what you are looking for?

1,236 views

Ask a Question

Usually answered in minutes!

Top Mitsubishi Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Are you a Mitsubishi Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...