Replaced blower motor was bad now new don't work and it is good motor what may be wrong
SOURCE: my blower motor isn't working properly. I hav
The motor ,or the fan selector switch,and connector most likely are the problem,check the fan,it could be at fault,or the switch,and connector,as for the floorboard being wet,it is most likely the drain for the evaporator is stopped up,look directly below where the ac lines go in the firewall(in the car from under the hood)the drain will be there,blow it out with air pressure,like a air tank,and blow gun.Water will pour out like a water fall if you get it clear.If this was helpful,please rate,and thank you.
SOURCE: front blower motor will not
This may be a faulty Blower motor resistor, usually mounted inside the blower motor air box, or defective blower motor. There is no single Relay for the blower motor.
I don't have a diagram for a 2008. On 2005 models the blower motor relay gets power from a 30amp fuse.
When the blower switch is in the high position the resistor is bypassed and power flows directly to the motor. The motor is grounded to the car.
The fan relay also gets power from a 7.5amp fuse and is controlled by the HVAC control on the dash.
Do you have power into and out of the relay?