2005 Mazda MPV Logo
Anonymous Posted on Oct 06, 2012

Cooling fan does not run? - 2005 Mazda MPV

4 Related Answers

Jonathan Dawson

  • 50 Answers
  • Posted on Aug 21, 2008

SOURCE: Cooling Fan Control

The cooling fan control module is located in front of the radiator. It should have 3 wiring harness's coming off of it.

I’m happy to assist further over the phone at https://www.6ya.com/expert/jonathan_3a3c556b4b17d1d2

Ad
allinallelec

binay biswas

  • 407 Answers
  • Posted on May 29, 2012

SOURCE: my 2005 mpv mazda cooling fan runs all the time when the engine is running and sometime when i shut the engine off the cooling fan keeps running but the van dont run hot

check battery volt & check line ware to system.

Tek Araga

  • 36 Answers
  • Posted on Oct 03, 2010

SOURCE: 05 mazda mpv cooling fan

check your thermoswitch for the fan...

Anonymous

  • 2926 Answers
  • Posted on Jul 01, 2011

SOURCE: I changed the middle cooling

You said "No, the fan did not stop when cooling fan relay was replaced. I have been driving the vehicle but fan has not come on again after shutting car off to test the other relays." Does this mean your issue is now resolved?

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Cooling fans on an 05 equinox runs continuously what can I do

Both radiator cooling fans are running all the time ? Key off ? The cooling fan opperation
HOW they work
Cooling Fan Control
The engine cooling fan system consists of 2 cooling fans and 3 relays. The relays are powered by the battery positive voltage circuit and controlled by a switched ground from the powertrain control module (PCM).
During low speed operation, the PCM supplies the ground path for the low speed cooling fan relay through the low speed cooling fan relay control circuit. This energizes the cooling fan low relay coil, closes the relay contacts, and supplies battery positive voltage from the COOL FAN LO fuse through the cooling fan motor supply voltage circuit to the cooling fan. During high speed operation the PCM supplies the ground path for the cooling fan low relay through the low speed cooling fan relay control circuit. After a 3-second delay, the PCM supplies a ground path for the cooling fan high relay and the s/p cooling fan relay through the high speed fan relay control circuit.
The PCM commands the fan on under the following conditions:
• Engine coolant temperature exceeds approximately 98°C (208°F) Low Fan Speed
• Engine coolant temperature exceeds approximately 102°C (216°F) High Fan Speed
• A/C refrigerant pressure exceeds 361 kPa (52 psi) Low Fan Speed
• A/C refrigerant pressure exceeds 2100 kPa (300 psi) High Fan Speed
• When the engine coolant temperature exceeds 112°C (234°F) at key off, the fan high speed will run for up to 300 seconds. If within that time frame 102°C (216°F) is reached then fan speed will change from high to low speed. If within that time frame 99°C (210°F) is reached then fan speed will change from low to off.
The PCM commands the fan off under the following conditions:
• A/C is requested and engine speed exceeds 6,240 RPM
• Engine coolant temperature exceeds approximately 99°C (210°F) turns the cooling fans from low to off.

sounds like one of the relays are stuck closed .

Cooling Fan Always On
Step
Action
Yes
No
Schematic Reference: Engine Cooling Schematics , HVAC Schematics in HVAC Systems - Manual
Connector End View Reference: Cooling System Connector End Views
DEFINITION: One or both engine cooling fan motors run continuously in high or low speed.
1
Did you perform the Diagnostic System Check - Vehicle?
Go to Step 2
Go to Diagnostic System Check - Vehicle in Vehicle DTC Information
2
Install a scan tool.
Turn ON the ignition, with the engine OFF.
With a scan tool, command the Fans Low Speed ON and OFF.
Are one or both cooling fans ON?
Go to Step 3
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems
3
Are both cooling fans running continuously?
Go to Step 4
Go to Step 6
4
Are both cooling fans running continuously in high speed?
Go to Step 5
Go to Step 7
5
Test the low reference circuit of the A/C refrigerant pressure sensor for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 18
Go to Step 14
6
Important: The S/P relay is located under the front bumper on the drivers side of the vehicle.
Remove the cool fan S/P relay.
Did the right cooling fan turn OFF?
Go to Step 10
Go to Step 8
7
Remove the cool fan LOW relay.
Did the cooling fans turn OFF?
0helpful
1answer

What does it mean on a 2007 saturn relay shut off air condition for engine maintenance

It means you should take your vehicle to a qualified repair shop , at least that's the car makers thought .
A/C Off For Engine Protection
Refer to Cooling System Description and Operation
Cooling Fan Control
The engine cooling fan system consists of 2 electrical cooling fans and 3 fan relays. The relays are arranged in a series/parallel configuration that allows the powertrain control module (PCM) or engine control module (ECM) to operate both fans together at low or high speeds. The cooling fans and fan relays receive battery positive voltage from the underhood junction block. The ground path is provided at G100.
During low speed operation, the PCM/ECM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. This energizes the cooling fan 1 relay coil, closes the relay contacts, and supplies battery positive voltage from the cool fan 1 maxifuse?® through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the cooling fan relay and the right cooling fan. The result is a series circuit with both fans running at low speed.
During high speed operation, the PCM/ECM supplies the ground path for the cooling fan 1 relay through the low speed cooling fan relay control circuit. After a 3 second delay, the PCM/ECM supplies a ground path for the cooling fan 2 relay and the cooling fan relay through the high speed cooling fan relay control circuit. This energizes the cooling fan relay coil, closes the relay contacts, and provides a ground path for the left cooling fan. At the same time the cooling fan 2 relay coil is energized closing the relay contacts and provides battery positive voltage from the cool fan 2 maxifuse?® on the cooling fan motor supply voltage circuit to the right cooling fan. During high speed fan operation, both engine cooling fans have there own ground path. The result is a parallel circuit with both fans running at high speed.
Are the radiator fans coming on ? You mite take it an have it checked for DTC'S - diagnostic trouble code's .
1helpful
1answer

My 07 Saturn Relay shows ac off for engine protection but the gauge shows cold. The hoses feel normal. What is happening?

A/C Off For Engine Protection
Refer to Cooling System Description and Operation

DTC P1258: Engine Coolant Overtemperature - Protection Mode Active.
This is something you need to take to a qualified repair shop .
The engine cooling fan system consists of 2 electrical cooling fans and 3 fan relays. The relays are arranged in a series/parallel configuration that allows the powertrain control module (PCM) or engine control module (ECM) to operate both fans together at low or high speeds. The cooling fans and fan relays receive battery positive voltage from the underhood junction block. The ground path is provided at G100.
During low speed operation, the PCM/ECM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. This energizes the cooling fan 1 relay coil, closes the relay contacts, and supplies battery positive voltage from the cool fan 1 maxifuse® through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the cooling fan relay and the right cooling fan. The result is a series circuit with both fans running at low speed.
During high speed operation, the PCM/ECM supplies the ground path for the cooling fan 1 relay through the low speed cooling fan relay control circuit. After a 3 second delay, the PCM/ECM supplies a ground path for the cooling fan 2 relay and the cooling fan relay through the high speed cooling fan relay control circuit. This energizes the cooling fan relay coil, closes the relay contacts, and provides a ground path for the left cooling fan. At the same time the cooling fan 2 relay coil is energized closing the relay contacts and provides battery positive voltage from the cool fan 2 maxifuse® on the cooling fan motor supply voltage circuit to the right cooling fan. During high speed fan operation, both engine cooling fans have there own ground path. The result is a parallel circuit with both fans running at high speed.
0helpful
1answer

Fan is not working on 2001 Chevy Silverado 2500 truck radiator fan motor?

The engine cooling fan system consists of 2 electrical cooling fans and 3 fan relays. The relays are arranged in a series/parallel configuration that allows the powertrain control module (PCM) to operate both fans together at low or high speeds. The cooling fans and fan relays receive battery positive voltage from the underhood fuse block.
During low speed operation, the PCM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. This energizes the low speed fan relay coil, closes the relay contacts, and supplies battery positive voltage from the low fan fuse through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the cooling fan s/p relay and the right cooling fan. The result is a series circuit with both fans running at low speed.
During high speed operation the PCM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. After a 3 second delay, the PCM supplies a ground path for the high speed fan relay and the cooling fan s/p relay through the high speed cooling fan relay control circuit. This energizes the cooling fan s/p relay coil, closes the relay contacts, and provides a ground path for the left cooling fan. At the same time the high speed fan relay coil is energized closing the relay contacts and provides battery positive voltage from the high fan fuse on the cooling fan motor supply voltage circuit to the right cooling fan. During high speed fan operation, both engine cooling fans have there own ground path. The result is a parallel circuit with both fans running at high speed.
Your best bet would be to take your vehicle to a qualified repair shop !
Relay Driven Dual Cooling Fan Diagnostics
2helpful
2answers

Where is the fuse for motor fan in uplander 2006?

there is 2 fuses that you have to check
one will be in the big fuse assembly in the engine bay, the other probably in the fuse assembly in the cab
If they prove ok then it is possible that the coolant temperature SENSOR is faulty and needs replacing
don't confuse it with the temperature sender which operates the temp gauge.
1helpful
1answer

My ac is not working I have a Chevy Tahoe 2005 the fans won't turn on either .

Hi Maria , The A/C system wouldn't keep the fans from running but none working cooling fans will keep the A/C from working ! This is a fairly complex system if your not familiar with this sort of thing ! I will add the description from the factory service manual.
Cooling Fan Control - Two Fan System
The engine cooling fan system consists of 2 electrical cooling fans and 3 fan relays. The relays are arranged in a series/parallel configuration that allows the powertrain control module (PCM) to operate both fans together at low or high speeds. The cooling fans and fan relays receive battery positive voltage from the underhood fuse block.
During low speed operation, the PCM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. This energizes the low speed fan relay coil, closes the relay contacts, and supplies battery positive voltage from the low fan fuse through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the cooling fan s/p relay and the right cooling fan. The result is a series circuit with both fans running at low speed.
During high speed operation the PCM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. After a 3 second delay, the PCM supplies a ground path for the high speed fan relay and the cooling fan s/p relay through the high speed cooling fan relay control circuit. This energizes the cooling fan s/p relay coil, closes the relay contacts, and provides a ground path for the left cooling fan. At the same time the high speed fan relay coil is energized closing the relay contacts and provides battery positive voltage from the high fan fuse on the cooling fan motor supply voltage circuit to the right cooling fan. During high speed fan operation, both engine cooling fans have there own ground path. The result is a parallel circuit with both fans running at high speed.
Do you have a check engine light lit ? The thing to do would have it check at the dealer or a ASE certified repair facility ! They could hook up a advanced scan tool an diagnose fairly quick ! Or you could find a wiring diagram an try testing with a volt meter yourself ! But watch yourself so you don't short out the PCM - engine computer !
0helpful
1answer

Cooling fan inop 1995 mustang gt 5.o

you can check the cooling fan by disconnecting the plug at the motor and run jumper wires from the battery directly to the fan motor it should run if its working if it doesn`t run then the cooling fan motor needs replacing. if it does run then check the plug for a bad connection. other things can cause this like the cooling fan relay, the coolant sensor that sends a signal for the computer to turn on the cooling fan by sending a signal to the relay.
0helpful
1answer

My 1994 Toyota Previa LE overheats when I put on AC. It overheats while on idle.

cooling fan not running.check for faulty cooling fan relay or fuse.cooling fan fan should be running when you turn on AC.hotwire cooling fan make sure cooling fan motor okay.
0helpful
1answer

Cooling fan not running as temp. heats up.

most time coolant temperature sensor faulty.but check cooling fan fuse and relay.then hot wire the cooling fan if fan runs.problem in the fan wiring or pcm.if every thing else okay.if cooling fan dont run when hot wired the cooling fan need replacing fan motor has internal open winding circuit.
2helpful
1answer

How do i check the cooling fan my car is over heating

HOT WIRE COOLING FAN USING JUMPER WIRES TO BATTERY.IF FAN DONT RUN WHEN HOT WIRED FAN MOTOR BAD NEED REPLACING. IF FAN RUN WHEN HOT WIRED. CHECK COOLING FAN FUSE AND RELAY.IF ALL IS GOOD.YOUR ENGINE COOLANT TEMPERATURE SENSOR NOT WORKING.IT CONTROL COOLING FAN AT SET TEMPERATURE IF SENSOR OPEN OR FAULTY THE COOLING FAN WONT TURN ON.CHECK COOLING FAN WIRES FOR DAMAGE.IF ALL STILL CHECK OUT GOOD HAVE VECHICLE SCANNED FOR PCM FAULT.IF IT FAILS NO COOLING FAN WONT TURN ON.
Not finding what you are looking for?

1,439 views

Ask a Question

Usually answered in minutes!

Top Mazda Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Are you a Mazda Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...