20 Most Recent 1994 Ford Taurus - Page 9 Questions & Answers

0helpful
1answer

What is code 0401 insufficient flow to EGR valve

A code P0401 likely means one ormore of the following has happened:
  • The DPFE (differential pressure feedback EGR) sensor is faulty and needs to be replaced
  • There is a blockage in the EGR (tube), most likely carbon buildup
  • The EGR valve is faulty
  • The EGR valve may not be opening due to a lack of vacuum
PossibleSolutionsTo fix this code, it is quite commonfor people to just replace the EGR valve only to have the OBD code return. TheEGR valve is not always the culprit.
  • Use a vacuum pump and pull the EGR valve open while monitoring engine RPM's & DPFE voltage. There should be a noticeable difference in RPM's with the EGR open
  • Clean out the EGR valve and/or tubing to remove deposits
  • Check the voltage at the DPFE, compare to specified values (refer to a repair manual for your specific model)
  • Replace the DPFE sensor (with a good quality / OEM one)
  • Replace the EGR valve
3/7/2012 1:21:19 AM • 1994 Ford Taurus • Answered on Mar 07, 2012
0helpful
1answer

Drivers side door wont seal,

latch has probably broke internally if you can slam door and dosent close replace latch maybe 15 dollars from a scrap yard and takes about 25 min max tools needed star screw driver and flat blade to take door panel off
2/16/2012 1:24:29 PM • 1994 Ford Taurus • Answered on Feb 16, 2012
0helpful
1answer

Open circuit to fuel pump

There is a 30 amp fuse in the underwood fuse block that is for the PCM/FUEL PUMP. It feeds power to the ccrm (constant control module relay). If there is no power to the inertia switch that is the first thing I would look at. It is the part located under the upper radiator support ne'er the battery. I’m happy to assist further over the phone at https://www.6ya.com/expert/jeremy_d728a59f986299fa
1/26/2012 1:47:49 AM • 1994 Ford Taurus • Answered on Jan 26, 2012
0helpful
1answer

I CHANGED THERMSATAT AND HAD HEAT FOR FEW DAYS NOW NO HEAT

could be your heater core
1/18/2012 9:37:51 PM • 1994 Ford Taurus • Answered on Jan 18, 2012
0helpful
1answer

I replaced the postive battery cable and now there is no power

did you clean the terminals good? Are both terminals tight? When you replaced the positive wire did you get all the other wires back on that were connected with that one? (if there were any)
12/30/2011 8:58:51 PM • 1994 Ford Taurus • Answered on Dec 30, 2011
0helpful
1answer

I was driving low on gas and my car died. I

check you,re fuel filter
11/24/2011 8:32:53 PM • 1994 Ford Taurus • Answered on Nov 24, 2011
0helpful
1answer

1994 Ford Tarus sometimes my 1994 ford tarurs will

Does it chick ? Mabe the starter starting to go bad. Does it start with a jump if so replace battery
11/15/2011 12:23:41 AM • 1994 Ford Taurus • Answered on Nov 15, 2011
0helpful
1answer

Back brake caliper's piston won't compress

if your turning the piston the right way which you probably are so it turns in not out and it won`t go back then it sounds like caliper needs to be replaced as the piston is siezed in its postion.
11/8/2011 8:30:41 PM • 1994 Ford Taurus • Answered on Nov 08, 2011
0helpful
3answers

Drive 5 miles and starts up fine, drive 30 miles and wont restart

Sounds like a fuel pump overheating. Drive until it wont start then check the fuel pressure. If no gauge when it wont start try some starting fluid. You should also check your fuel pump relay.
11/6/2011 2:30:17 PM • 1994 Ford Taurus • Answered on Nov 06, 2011
0helpful
1answer

1994 ford taurus leaks gas

The fuel filter is located on the passenger side just in front of the passenger rear tire. That would be the first thing I checked. It is not uncommon for the filters to rust through. It is also not uncommon for the lines to leak at the fittings or for the lines to crank. A good inspection of this area should make the source of the leak fairly easy to figure out.Good luck, let me know if you have any questions. Thank you for using Fixya.com! I’m happy to assist further over the phone at https://www.6ya.com/expert/jeremy_d728a59f986299fa
11/4/2011 5:04:43 PM • 1994 Ford Taurus • Answered on Nov 04, 2011
0helpful
1answer

Running lean

I know the water temp sensor and air flow sensor can cause that. There are other possible solutions but, the Water temp sensor plugs into the intake it adds fuel when water is cold and gives less fuel when the water gets warm -- the air flow sensor will add and take away fuel depending on quantity and quality of air.
10/12/2011 2:54:48 PM • 1994 Ford Taurus • Answered on Oct 12, 2011
0helpful
1answer

After changing out the radiator the fan comes on

It is not the PCM. The fan on all the time says you may be in failure mode, with fixed values by the PCM. You disconnected something electrical during the radiator swap out. The fule pump should come on for 5 seconds when you turn key to ON, and humm. Then turn off.

The power relay should turn on the PCM, which in turn, turns on the fuel pump relay to acitvate the fuel pump. Check the power relay first.

I think this relay is under the hood in the relay box. See owner manual.
10/11/2011 1:49:57 AM • 1994 Ford Taurus • Answered on Oct 11, 2011
Not finding what you are looking for?

896 questions posted

Ask a Question

Usually answered in minutes!

Popular Products

1999 Ford Taurus
1999 Ford Taurus

2,348 Questions

2001 Ford Taurus
2001 Ford Taurus

2,262 Questions

2000 Ford Taurus
2000 Ford Taurus

2,120 Questions

2002 Ford Taurus
2002 Ford Taurus

1,869 Questions

1998 Ford Taurus
1998 Ford Taurus

1,431 Questions

Top Ford Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Taurus Ford

  • Taurus Ford

Most Popular Question

1994 ford taurus new plugs new

  • Cars & Trucks
Loading...