20 Most Recent
1990 Acura Integra Questions & Answers
Low humming noise and burnt plastic smell coming from 1990 acura integra
Jennifer what type of timing belt does your engine use ?
Is it Nylon ? When was the last time you had it changed ?
Burning plastic smell may be being caused by the timing belt bearing runners seizing and the belt is getting hot .
If the belt is due to snap you could cause a lot of damage to the engine if it breaks.
Might be worth getting a mechanics advice on this as a possible cause
How do you check the side view mirror switch on
Remove the door panel so you can access the wire that plugs into the mirror control. Use a 12 test light to determine which wire provides power to the switch. (key on engine off) Once the power terminal is identified (key on engine off) use a jumper wire to send power to the mirror motors. There should be five terminals one for power, one for each direction. If they all work the switch is bad. If no power, open circuit so blown fuse. If they don't work bad mirror motors
Thermostat housing
By the sounds of it, it may well be seized in, make sure you have soaked it with a penetrant like fospro, leave for a few hours, then get a high impact socket that fits exactly right, give it a whack vibration helps loosen all the build up. If this doesn't work and you have a ally head, you can't really apply heat. You may end up shearing the head off the bolt then re drill and thread the hole. It does happen unfortunately and can't be helped sometimes.
Car not starting
sounds like you may have a starter relay issue or maybe the starter it self. also did you check any relays that are associated with the ignition? I am going to bet the relay or starter..good luck
Carstartsandrunsfortenminutes,thenshutsdown
does it start as soon as it stops possible fuel problem (pump)or fire computer under carpet on pass side floor corosion on the wires heats up causing short or relays in fuse boxes overheat shut down no carstarter installed no anti theft these are things to check
How to Clean a Solenoid Starter in Acura integra car?
1) Keep the starter on a clean surface.
2) Clean the starter with lubricant cleaner.
3) Remove the motor from starter by removing the bolts holding the starter.
4) Clean the bolts also with the lubricant cleaner.
5)After the bolts are removed the stater will come out.
the inner cylinder connected to the starter will not come out.it will remain in place.
6) Properly clean all the components with lubricant cleaner.
7) Use cleaning brush and rag to clean all the inner components.
8) The starter is cleaned now.
8) Then reassemble all the components back.
This will help.Thanks.