Ultra Products Electrical Supplies - Recent Questions, Troubleshooting & Support

0helpful
1answer

Guardian Ultra Source 17,500 Watt Emergency Power System - 4583: donot have a problem am wondering the dependabilit...

These are obviously opinionated answers however, I have had mine wired to my home for approximately 9 years and have had only 1 issue where a voltage regulator failed. The new regulator cost me just over $100.00 and was easy to replace. I crank my generator once every couple of months by adding about 1/2 gallon of fuel and let it run till empty. Never use fuel that has Methane as this fuel absorbs water and will damage fuel components if you leave fuel in your generator. If you leave empty as I do, it has had no effect thus far.
3/25/2013 8:58:13 PM • Ultra Products... • Answered on Mar 25, 2013
0answers
0helpful
1answer

Cranking, will start using ether... oil is full,

You probably have a clogged main jet in the carb. You have to remove the float bowl to access the main jet, it is a brass orifice that is removed with a slotted screwdriver. Most of the time you don't actually have to remove the jet to clean it. Spray carb cleaner into the jet, let sit for a couple of minutes then blow it out with compressed air. Becareful not to spray into your eyes. You may have to do this a couple of times to get all the junk out.
11/21/2009 12:08:43 AM • Ultra Products... • Answered on Nov 21, 2009
0helpful
1answer

Cranks but will not start

Have you checked or changed the oil? If the oil is low it will not start.
6/3/2009 9:39:31 PM • Ultra Products... • Answered on Jun 03, 2009
0helpful
1answer

Fuel supply

no. the generator fuel is gravity feed.
you can install a fuel pump, but then you going to need additional wiring and hardware.
4/9/2009 2:54:01 PM • Ultra Products... • Answered on Apr 09, 2009
0helpful
1answer

I have a slight power surge on my 15,000 ultra source

that linkage is suppose to move. The more power draw the more the linkage moves
2/2/2009 12:18:50 PM • Ultra Products... • Answered on Feb 02, 2009
0helpful
1answer

Manual for scorpion sl2800 generator

Yes
4/9/2024 2:32:16 AM • Electrical... • Answered on Apr 09, 2024
0helpful
2answers

My conlog meter is showing the rfcon error please what do I do

No connecting to your utilty company in South Africa. Just FYI, we are a North American site and my not always have the answer, in this case we do Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error-cant-do-anything-on-the-gadget-please-help-on-how-to-re/962048393965724/ Quoting from link above: "Conlog Hi Ola-daniels, Please see below steps to assist with RFCON error : * Press the Back arrow on the keypad - this step is to refresh the UIU ( the device) * Type # 75 # - this is to check the signal strength If it does not go back to the normal display *Type # 80 # - this is to refresh the meter Then lastly you can repair the meter and the UIU by # 36 # The above steps will work better if you are outside the house because the meters uses the radio frequency connection The above error will occur in instances of bad weather conditions or if there is load shedding or power failure If the problem persists after trying the above you may contact the municipality or the service provider."

SOLVED: How do I clear up the rf con error on my meter ...

https://www.fixya.com > ... > The
May 7, 2020 - How do I clear up the rf con error on my meter because I want to ... Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error- ... Hi Ola-daniels, Please see below steps to assist with RFCON error : ... shut down the energy alimentation for 2 minute ,but if the defect persist error it show again. SOLVED: Pole meter conlog rf con meter keep on freezing ... Jan. 10, 2017 Meter reading shows rF CON instead of units available - Fixya Jun. 24, 2018 SOLVED: Good day my conlog ip54 elecricity meter showd ... Oct. 6, 2018 SOLVED: Rf con error - Fixya Jun. 20, 2020 More results from www.fixya.com

Please Help With My Conlog Prepaid Meter - Technology ...

https://www.nairaland.com > please-conlog-prepaid-meter
Aug. 6, 2020 - ystar: If the conlog meter is showing rf-Con, it means power supply doesn't reach the meter at all its either Loss of phase from the transformer or a loose contact ... How Do I Load The Activation Token On My Conlog Prepaid ... Mar. 17, 2020 I Need A Technician To Fix This... - Nairaland / General - Nigeria Jul. 22, 2019 I Need Number Codes To Reset Memmcol Prepaid Meter ... Jan. 11, 2019 More results from www.nairaland.com
3/24/2024 3:42:46 AM • Electrical... • Answered on Mar 24, 2024
0helpful
1answer

Wiring 3 lights 3 separate switches

Consult a qualified electrician.
3/23/2024 7:13:23 AM • Electrical... • Answered on Mar 23, 2024
0helpful
1answer

Kawasaki GA1400A Generator. It starts fine, 12 volts okay, but no 230 volts.

Question edited for clarity. Question moved from Motorcycles to Generators category. Some help in the link, but not as much as I would like https://www.google.com/search?q=Kawasaki+GA1400A+no+230+volts+output ..
2/11/2024 5:52:06 AM • Electrical... • Answered on Feb 11, 2024
0helpful
1answer

GE outdoor 200A fusible disconnect can not stay on position, how to fix this issue

It has a cantilever snap action. Either the spring has detached, broken, disabled or unit is otherwise damaged. Heat, water, rodent, etc damage. Replacing the unit is most likely your only option.
2/9/2024 12:37:45 PM • Electrical... • Answered on Feb 09, 2024
0helpful
1answer

What are the valve specs for a kubota av3800 generator

I want PDF AV 3800 Generator
2/8/2024 2:59:27 AM • Electrical... • Answered on Feb 08, 2024
0helpful
1answer

Can i use this tester to check for any live wires. im installed a new light fixture on my porch from existing wiring but lights not tuning on

However, I can provide guidance on using a basic voltage tester to check for live wires when troubleshooting a light fixture installation. Using a Voltage Tester: Non-Contact Voltage Tester: If you have a non-contact voltage tester, it's a handy tool for quickly identifying live wires without direct contact. Hold the tester close to the wire insulation or the terminal screws, and it should indicate the presence of voltage without making physical contact. Contact Voltage Tester: If you have a contact voltage tester, make sure it's designed for the voltage level you're working with (e.g., 120V for residential electrical systems). Turn off the strength to the circuit on the circuit breaker or fuse box. Safety First: Always prioritize safety. Make sure the power is turned off before working on any electrical components. Test the Tester: Test the voltage tester on a known live circuit to ensure it's functioning properly. Check the Wiring: Once confirmed, turn off the power to the circuit you are working on. Use the voltage tester to check each wire connected to the light fixture. Verify that there is voltage on the wires. Neutral and Hot Wires: Typically, a light fixture will have a hot wire (usually black) and a neutral wire (usually white). Make positive each wires are linked properly. Ground Wire: Check for a ground wire and ensure it's properly connected. Some light fixtures may have a green or bare copper wire for grounding. Switch Position: Ensure that the wall switch controlling the light fixture is in the ON position. Bulb Check: Confirm that the light bulbs in the fixture are working and properly installed. Circuit Breaker Check: Double-check the circuit breaker or fuse for the lighting circuit to make sure it hasn't tripped or blown.
1/22/2024 4:17:43 PM • Electrical... • Answered on Jan 22, 2024
0helpful
1answer

I have a onan 4000 LP generator when I try to start it it starts and then goes dead?

Here are some common troubleshooting steps to help you identify and potentially resolve the problem:
  1. Fuel Supply:
    • Check the LP (propane) fuel supply. Ensure that there is enough propane in the tank.
    • Check for any obstructions or kinks in the fuel line.
  2. Air Intake and Exhaust:
    • Make sure the air intake and exhaust are not blocked. Lack of proper ventilation can cause the generator to shut down.
  3. Choke Position:
    • Check the position of the choke. If it's set to "Choke" for starting, make sure to gradually move it to the "Run" position once the generator has started.
  4. Fault Codes or Indicator Lights:
    • Look for any fault codes or indicator lights on the generator control panel. These can provide clues about specific issues.
  5. Oil Level:
    • Check the oil level in the generator. Some generators have a safety feature that shuts them down if the oil level is too low.
  6. Spark Plug:
    • Inspect the spark plug for fouling or damage. If needed, clean or replace the spark plug.
  7. Fuel System Issues:
    • Inspect the fuel system for any leaks or issues. LP generators may have a fuel filter that needs to be checked and, if necessary, replaced.
  8. Carburetor:
    • The carburetor may need cleaning or adjustment. If it's clogged, it can lead to stalling issues.
  9. Battery Voltage:
    • Ensure that the generator's battery has sufficient voltage. A weak or dead battery can affect the starting process.
  10. Generator Load:
    • If the generator is under a heavy load, it may shut down. Try starting it without any load and then gradually add loads.
1/22/2024 4:11:03 PM • Electrical... • Answered on Jan 22, 2024
0helpful
1answer

What is the valve clearance on a Duramax 13000 generator?

Most Duromax OHV engines are as follows with engine cold (ambient air temperature).0.006 in. intake 0.008 in. exhaust
1/16/2024 9:25:36 PM • Electrical... • Answered on Jan 16, 2024
Not finding what you are looking for?
Ultra Products Logo

6 questions posted

Ask a Question

Usually answered in minutes!

Top Ultra Products Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66931 Answers

Are you an Ultra Products Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...