I have an 1850 Coleman powermate that spews gas from gas cap vent, replaced with new one and still does it. How do I fix?
Troubleshoot this problem:
Check Fuel Level: Ensure that the fuel level is not too high. If the tank is filled to the brim, it might cause excess pressure and lead to fuel spewing from the vent.
Gas Cap Design: Some gas caps have a metal cone inside to deflect fuel away from the vent hole. Make sure you have the correct gas cap for your generator. The vent hole may not go through the top of the cap but vents under the gasket inside it.
Vapor Lock: Coleman customer support suggests that vapor lock could be a possible cause. Try the following steps:
Clean the carburetor and its bowl.
Disconnect the gas line to ensure it's clear.
Use fresh fuel.
Inspect the Gas Cap: Double-check that the new gas cap you installed matches the correct part number according to the parts list.
Replace the Gas Cap: If all else fails, consider getting a replacement gas cap specifically designed for your Powermate 1850 generator. You can find suitable gas caps online or at authorized dealers.
PowerMate Formerly Coleman Gas Caps 4-Cycle - Jacks Small Engines
4/19/2024 5:18:05 AM •
Coleman...
•
Answered
on Apr 19, 2024
Fix overtemp light on in kipor kde6700ta diessel generator
The overtemp light on the Kipor KDE6700TA diesel generator indicates that the engine is overheating. Here are some steps you can take to try to resolve the issue:
- Turn off the generator immediately and let it cool down. Check the coolant level in the radiator and top it off if it is low. If the coolant level is consistently low, check for leaks in the coolant system and repair them.
- Check the radiator fins for any blockages that may be preventing airflow. Clean the fins using compressed air or a soft brush.
- Check the fan belt tension and replace the belt if it is worn or loose. A loose belt can cause the fan to rotate at a slower speed, reducing the cooling capacity of the radiator.
- Check the thermostat to ensure that it is functioning correctly. If the thermostat is stuck in the closed position, it can cause the engine to overheat.
- Check the water pump to ensure that it is working correctly. A faulty water pump can reduce the flow of coolant through the engine, causing it to overheat.
- If you have tried all the above steps and the overtemp light is still on, it may be necessary to replace the thermostat, water pump, or other cooling system components. It's recommended to contact Kipor customer support or a qualified technician for further assistance.
Once you have resolved the issue, start the generator and let it run for a few minutes to ensure that it is operating at the correct temperature. Keep an eye on the overtemp light to ensure that it does not come back on.
My conlog meter is showing the rfcon error please what do I do
No connecting to your utilty company in South Africa. Just FYI, we are a North American site and my not always have the answer, in this case we do
Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error-cant-do-anything-on-the-gadget-please-help-on-how-to-re/962048393965724/
Quoting from link above: "
Conlog Hi Ola-daniels, Please see below steps to assist with RFCON error :
* Press the Back arrow on the keypad - this step is to refresh the UIU ( the device)
* Type # 75 # - this is to check the signal strength
If it does not go back to the normal display
*Type # 80 # - this is to refresh the meter
Then lastly you can repair the meter and the UIU by # 36 #
The above steps will work better if you are outside the house because the meters uses the radio frequency connection
The above error will occur in instances of bad weather conditions or if there is load shedding or power failure
If the problem persists after trying the above you may contact the municipality or the service provider."
SOLVED: How do I clear up the rf con error on my meter ...
https://www.fixya.com > ... > The
May 7, 2020 - How do I clear up the rf con error on my meter because I want to ... Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error- ... Hi Ola-daniels, Please see below steps to assist with RFCON error : ... shut down the energy alimentation for 2 minute ,but if the defect persist error it show again.
SOLVED: Pole meter conlog rf con meter keep on freezing ...
Jan. 10, 2017
Meter reading shows rF CON instead of units available - Fixya
Jun. 24, 2018
SOLVED: Good day my conlog ip54 elecricity meter showd ...
Oct. 6, 2018
SOLVED: Rf con error - Fixya
Jun. 20, 2020
More results from www.fixya.com
Please Help With My Conlog Prepaid Meter - Technology ...
https://www.nairaland.com > please-conlog-prepaid-meter
Aug. 6, 2020 - ystar: If the conlog meter is showing rf-Con, it means power supply doesn't reach the meter at all its either Loss of phase from the transformer or a loose contact ...
How Do I Load The Activation Token On My Conlog Prepaid ...
Mar. 17, 2020
I Need A Technician To Fix This... - Nairaland / General - Nigeria
Jul. 22, 2019
I Need Number Codes To Reset Memmcol Prepaid Meter ...
Jan. 11, 2019
More results from www.nairaland.com
Pramac px5000 plug stuck in ac socket
If the plug of your Pramac PX5000 generator gets caught in an AC socket, follow these steps: 1. Turn off the electricity to the socket.2. Wear insulated gloves for safety.3. Gently wiggle the plug while pulling it out.4. Apply a bit of lubricant if needed.5. Use insulated pliers to grip and pull the plug.6. If you cannot take it away, get help from an expert electrician to keep it away from harm or injury.
3/19/2024 1:25:41 PM •
Pramac...
•
Answered
on Mar 19, 2024
Steamist Steam Generator.
When I start my steam generator it stops at 32 temperature giving double EE error. What should I do?
Question edited for clarity and spelling of the maker.
Question moved from Laundry Irons category.
I found this
On 2021-12-23 by Inspectapedia Com Moderator - Diagnose & Clear an EE error code on some Steam Generators
@mike c,
Diagnose & Clear an EE error code on some Steam Generators:
What are the brand and model of your steam generator?
I ask because error codes are not universal across all steam generator brands and models.
But on the off chance we can GUESS usefully
Your steam generator may be receiving water at an excessive pressure. We've seen this EE error code reported for Happybuy Steam Generators (Amazon):
Check the water pressure being delivered to your unit to be sure it's not higher than is permitted by the IO manual or try reducing the supply pressure to 5 psi.
Then turn the unit off and drain pressure from the unit. Leave it off for a few minutes or longer. Then return power and water supply - at 5 psi.
More here including a link to the maker
https://www.google.com/search?q=steamist+steam+generator+ee+error+code
..