The defrost drain line probably is located in the bottom rear, depending upon configuration. It is not a plug.

Kenmore... | 406 views | 1 helpful votes


One thing it could be is that the water solenoid not closing completely. Water drips from fill tube into icemaker and freezes, not allowing any water to get through. This is fairly common and with a couple of tools, you might be able to fix it yourself if you're handy. Could be other causes too, this is the one i'm familiar with.
UPDATE> If the water filler tube that empties into the tray is frozen solid, then it;s probably the water solenoid (not shutting off).. And you want to avoid cycling the system (the heating element coming on) without water in the tray. That's what i saw in a video. Hope that helps.

Kenmore... | 513 views | 1 helpful votes


Some do have a diagnostic mode and some do not. Each model is different and we really need to have a model# to help troubleshoot any issues. You also did not say what the issue is?

Kenmore... | 99 views | 1 helpful votes


Please post your model number for Kenmore product so we know what exactly we dealing with

Kenmore... | 51 views | 0 helpful votes


If your coils are froze up, this could be temperature sensor I believe or your defrost valve, usually back in the fridge is your coils if they are frozen solid you need to unplug refrigerator freezer let it thaw out, you will have lots of water so get towels and stuff to soak up your water once it is thawed,plug frigerator freezer back in give it time to cool back down if the refrigerator side is cool now then I would say defrost valve or temperature sensor will need replaced there also should be a fan that blows the cold air into your refrigerator,, was it run for about a day or so if it starts freezing up again that's more proof defrost valves not working

Kenmore... | 42 views | 0 helpful votes


CALL YOUR LOCAL REPAIR SERVICE IT NEEDS TESTED AND WE CAN NOT DO IT FROM HERE

Kenmore... | 408 views | 1 helpful votes


On some refrigerators you must push in first to release the filter.

Kenmore... | 25 views | 0 helpful votes


look on the plate were you got the modal number

Mike

Kenmore... | 37 views | 0 helpful votes


Your machine was probably knocked or dropped during transport and something is now obstructing the fan.
Your question did not say what kind of machine you have.
If it is an oven, you might find this link helps.
https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=2&cad=rja&uact=8&ved=2ahUKEwjHkOfHs-jhAhUEixoKHSXqB6UQwqsBMAF6BAgHEAQ&url=https%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3Ds2XCm88Mm8g&usg=AOvVaw1IvX0yNoMCc88U8UHsOAx3

If this answers your problem, please leave good feedback, thanks.

Kenmore... | 74 views | 0 helpful votes


A simple way to get a rough idea is to measure it.
Measure inside the refrigerator, Just the space where the shelves and food would be.
Measure top to bottom, front to back and left to right.
multiply these numbers together. The maths might be easier if you use inches and divide the answer by 12.

Kenmore... | 26 views | 0 helpful votes


tripping circuit may be a short in system, you can check the compressor I have attached pics and short explaination how to do that. as for the water leak? sounds more like either a condensation issue from a bad seal indoor gasket somewhere, ( see pics) or a clogged drain plug not allowing it to drain properly.
THE COMPRESSOR:
If you hear a clicking sound coming from the back of your refrigerator/freezer, then the problem is most likely the compressor, relay and or capacitor is overheating or not getting proper power and will not start.The compressor is the component on your refrigerator that allows your refrigerator to cool. If this component is not working properly your refrigerator will stop cooling. Most of the time the compressor is not the component that has failed.

To check ur compressor with multi meter:
Disconnect and remove the relay and capacitor from compressor, some located next to compressor in a casing.

You wills see 3 prongs coming out of compressor. 1 goes to ur start winding, 1 goes to ur run winding and the center goes to ur ground.

Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms.
Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms

Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms.Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short in ur compressor. It should show infinity

TO REPLACE RELAY AND CAPACITOR WITH A HARDSTART KIT YOU CAN USE

A 3 in 1 start kit for compressors sizes 1/4 through 1/3 HP. And a 5 in 1 for higher H.P. (BE SURE TO MATCH WITH UR COMPRESSOR MODEL NUMBER AND TYPE) The kit includes relay, capacitor, and overload device, pre-wired. The kit will replace all 3 electrical components on capillary refrigeration systems. For newer systems with a run capacitor use proper kit. For smaller horsepower compressors useTJ90RCO810.

The wire set up is as follows the red wire goes to the right side of compressor prong, the white wire to the left side prong, the black wire to the center prong, and the 2 other black wires go to the power and the ground connection


Lastly you should also check ur THERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS currentbeing put out. In most models around 13000 ( give or take 150 ohms) ohms is required.

Fridge not starting? CLICKING?FIRST ALWAYSCHECK FORpower at the outlet,checkfor 120 volts.

MAY HAVE A BAD START RELAY OR CAPACITOR ON THE COMPRESSOR , CAN BUY A INEXSPENSIVE 3 IN 1 HARDSTART KIT AND BY PASS THEM , NOT THAT HARD TO DO, COMES WITH INSTRUCTIONS> BY THE WAY DO U HEAR ANY CLICKING SOUNDS FROM COMPRESSOR? BUT U MAY ALSO WANT TO CHECK UR COLD CONTROL THERMOSTAT IF IT GOES BAD U MAY GET A NON START ALSO HAVE IT CHECKED FOR PROPER VOLTAGE AND OHMS RESISTANCE WHEN IN THE ON POSITION
A BAD DEFROST TIMER though seldom CAN SHUT DOWN COMPRESSOR HAVE IT CHECKED WITH MULTI METER.

to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.

Take ur meter prong and connect to prong 1 & 4, it should readresistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click.

Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS.
And adjusting to low ohms rating may give a false reading or not show the proper resistance..
Some fridges are now using ADC boards.
Designers are using microprocessors (on solid state circuit boards) to adapt defrost intervals and durations to compensate for differences and changes in operating conditions. Such techniques are calledAdaptive Defrost Control, commonly abbreviated as ADC. They are normally found in same locations as the timer would be but look somewhat different in appearance. It is more difficult to test these units without the appliance schematic.
Some ADC / control boards control other functions of the refrigerator, too, such as icemaking and electrical air damper door opening and closing.The defrost frequency may also be shortened under certain circumstances.
AT TIMES YOU MAY HEAR THE COMPRESSOR CLICK OFF AND ON OVER AND OVER. Signs of a bad start relay or capacitor. Check with an OHMS meter for continuity (ohms) and voltage, capacitor can be checked for Microfares. ( if in series with the windings)

If you hear your compressor "short-cycling" (starting and stopping at short intervals) try jumping across the two leads of the cold control thermostat ( in the fridge compartment) with an alligator jumper. You can also check both for live voltage current and ohms- If there is a greenthirdlead, ignore it for this test; it is the ground wire. If the fridge starts running constantly, the cold control is bad. Replace it.
To check ur compressor with multi meter:
Disconnect and remove the relay and capacitor from compressor, sometimes located next to compressor in a casing.

You wills see 3 prongs coming out of compressor. 1 goes to ur start winding, 1 goes to ur run winding and the center goes to ur ground or COM

Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms.
Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms

Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms.Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms, u have a short in ur compressor. It should show infinity
God is so good: so this is why I give free advice so please thank him not me.


TO REPLACE RELAY AND CAPACITOR WITH A HARDSTART KIT YOU CAN USE

A 3 in 1 start kit for compressors sizes 1/4 through 1/3 HP. And a 5 in 1 for higher H.P. (BE SURE TO MATCH WITH UR COMPRESSOR MODEL NUMBER AND TYPE) The kit includes relay, capacitor, and overload device, pre-wired. The kit will replace all 3 electrical components on capillary refrigeration systems. For newer systems with a run capacitor use proper kit. For smaller horsepower compressors useTJ90RCO810.

The wire set up is as follows the red wire goes to the right side of compressor prong, the white wire to the left side prong, the black wire to the center prong, and the 2 other black wires go to the power and the ground connection


http://www.appliancerepair.net/refrigerator-repair-1.html

https://www.youtube.com/watch?v=-L80Fk5had4defrost timer



compressor testcompressorwindings-wjhymyfw2vrrkydsdijejsqx-1-0.jpg

door seals cracked-fridge-seals-wjhymyfw2vrrkydsdijejsqx-1-2.jpg

door seals test +refrigerator+seal+test-wjhymyfw2vrrkydsdijejsqx-1-5.jpg

drain center drain holer-wjhymyfw2vrrkydsdijejsqx-1-14.jpg

drain plug in tt 006e-wjhymyfw2vrrkydsdijejsqx-1-20.jpg

door seals -replace-a-refrigerator-door-seal-step-10-wjhymyfw2vrrkydsdijejsqx-1-27.jpg

Kenmore... | 32 views | 0 helpful votes


since no model go to kenmores site and look up owners manual if newer most are frost free

Kenmore... | 34 views | 0 helpful votes

Not finding what you are looking for?
Kenmore Logo

15,646 questions posted

Ask a Question

Usually answered in minutes!

Top Kenmore Refrigerators Experts

Fred Sops

Level 2 Expert

351 Answers

Audrey Messer
Audrey Messer

Level 2 Expert

182 Answers

Jimmy

Level 2 Expert

49 Answers

Are you a Kenmore Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...