You probably have done this, but......try a new and top line USB cable. rj

Fisher... | Answered on Sep 29, 2017


Note: Administrator default password is admin.

Science &... | Answered on Sep 27, 2017


Here are the instruction for installing the QX3 (or QX3+) Microscope with Vista and Windows 7. You must be using a 32-BIT VERSION. The QX3 is not compatible with 64-bit versions.

Note, DO NOT use the software from the CD that came with the microscope.
DO NOT plug in the QX3 microscope until Step 4.

Step 1. Download and install the QX3PLUS.EXE software from Intel:
http://tinyurl.com/QX3-Win7-Files

Step 2. Download and install the QCODINSTL.EXE software from:
http://tinyurl.com/QX3-Win7-Files

Step 3. Download and extract the QX3 Drivers from:
http://tinyurl.com/QX3-Win7-Files

Step 4. Now, plug in the microscope.
When the "Found New Hardware" wizard appears you will see a message saying that the driver installation was not successful. Click the Close box. You need to install the driver manually by following these steps:
a. Click START - Select Devices & Printers
b. Right-click on the Intel QX3 Icon and select Properties
c. Click the Hardware tab - click Properties
d. Click Update Driver - select "Browse my computer for driver software"
e. Browse to the folder with the extracted QX3 drivers from Step 3. above. The driver software should install successfully.

Before you run the QX3Plus program right click the icon, click on "Properties", click the "Compatibility" tab, check the box next to "Run this program in compatibility mode for:", then choose in the drop-down box "Windows 98 / Windows ME". You should also check "Run as Administrator" if your account is a "Standard user".

Step 5. Now double-click on the QX3+ icon on the desktop and the program should run.
------------

Intel Play QX3... | Answered on Sep 16, 2017


Damage to an expensive precision instrument can result in loss of functions, distorted results, costly repair or replacement. There is also risk of contamination and injury. Damage can result from misuse or lack of maintenance.

Safety Maintenance

http://www.wpro.who.int/mvp/lab_quality/2096_oms_gmp_sop_12.pdf

Science &... | Answered on Sep 09, 2017


Service Support Nikon Instruments Microscopes and Imaging Systems

My best advice is to contact the support for the instrument. Avoid DIY without expert guidance as the potential for damage to the precision instrument exists which could result in costly repair or replacement.

Nikon Science &... | Answered on Sep 09, 2017


There are a variety of brands/models of autoclaves and your model is not adequately identified. There are ES models of an autoclave of a particular brand but I have no knowledge of their designation system. A search of an autoclave manual did not reveal an "es" error code. Why not contact technical support or the sales forces of the manufacturer with the query?

Science &... | Answered on Sep 09, 2017


The "pot" really adjustable electrical resistance feed in the bulb directly of through a triac is most likely showing intermediate contact between the resistance coil and "slider" - it will have to be replaced.

Wesco CXR3... | Answered on Aug 28, 2017


The connect wire might be broken or the print.....

Science &... | Answered on Aug 22, 2017

Not finding what you are looking for?
Science & Laboratory Logo

2,350 questions posted

Ask a Question

Usually answered in minutes!

Top Science & Laboratory Experts

Gareth Cockram
Gareth Cockram

Level 3 Expert

661 Answers

William McMath

Level 2 Expert

178 Answers

ray gallant

Level 3 Expert

46218 Answers

Are you a Science and Laboratory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...