Office Equipment & Supplies - Page 4 - Recent Questions, Troubleshooting & Support


Goto the Xerox.com website.
Sorry,
Good luck.

Xerox Workcentre... | Answered 16 hours ago


Replace cartridge. Sometimes it is out of alignment as it is not seated.

In Office... | Answered 17 hours ago


CD 010 is unformatted hard drive

CD030 is admin data not on hDD

Konica Minolta... | Answered 22 hours ago


H4 00 Content Main heater lamp abnormally low
temperature detection
Details The setup temperature (about 90°C) is not
reached within the specified time (about
17sec) from turning on the power ON SW.
(When the temperature of main heater
lamp thermistor falls below 140°C in the
standby mode or printing.)
Whether temperature of main heater lamp
thermistor falls below 50°C in the pre-heat
mode.
Cause Main heater lamp thermistor defect
Main heater lamp failure
Main thermostat failure
Control PWB failure
Check and remedy
Check the heater lamp blinking with SIM 52.
When the lamp blinks normally:
Check the thermistor and the harness.
Check the MCU PWB thermistor input
circuit.
When the lamp does not light:
Check for disconnection of the heater
lamp and thermostat.
Check the interlock switch.
Check the power PWB and the MCU PWB
lamp control circuit.
Clear the display of self-diagnostics with
SIM 14.

Sharp Office... | Answered 24 hours ago

Not finding what you are looking for?
Office Equipment & Supplies Logo

577,489 questions posted

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

kakima

Level 3 Expert

102366 Answers

jasbo
jasbo

Level 3 Expert

2237 Answers

yadayada
yadayada

Level 3 Expert

76846 Answers

Are you an Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...