Plumbing - Page 6 - Recent Questions, Troubleshooting & Support

0helpful
1answer

I can't get my Belle Foret faucet apart to replace the diverter?

A suggestion here, in fact 2 :>D https://terrylove.com/forums/index.php?threads/belle-foret-faucet-repair.81430/ But he is right, this is a niche, unknown make. One video https://www.google.com/search?q=belle+foret+faucet+replace+diverter There is no maker listed which usually means they are made in China or Korea https://www.google.com/search?q=belle+foret+faucet ....
11/11/2022 6:35:27 PM • Belle Foret... • Answered on Nov 11, 2022
0helpful
1answer

Cannot remove Kohler ceramic valve

is this a single handle faucet. If not the part goes in under the handle
11/2/2022 2:55:20 PM • Kohler Model... • Answered on Nov 02, 2022
0helpful
1answer

Brand new Delta faucet and battery case will not stay closed. Only one week old!

Question moved from Cars and Trucks to Delta Plumbing. If it is brand new, you need to contact Delta under warranty rather than Fixya. https://www.google.com/search?q=Delta+faucet+and+battery+case+will+not+stay+closed ..
10/30/2022 3:18:58 PM • Delta Plumbing • Answered on Oct 30, 2022
0helpful
1answer

There is a plastic nut that is keyed in 2 spots so that it requires a custom tool to remove on the pull out spray head. How do I find this custom tool?

Try the Kohler web site . Some of the big box store do them but not all. Wosleys might .
10/29/2022 9:16:52 PM • Kohler Model... • Answered on Oct 29, 2022
0helpful
2answers

I have a Grundfos Scala 2 Self Priming Pressure Booster Pump that keeps running.

sounds like a pressure cut off switch issue that senses when the water is turned off. https://www.google.com/search?q=grundfos+scala+2+doesn%27t+switch+off ..
10/21/2022 8:06:11 AM • Grundfos... • Answered on Oct 21, 2022
0helpful
2answers

Moen motion sensor faucet

Check the power to it, battery or transformer unit. Ensure that the data cable and power source cable (battery pack or AC adapter) are plugged in tight and secure. Check Batteries: If using a battery pack, ensure the batteries are installed correctly and are snug in the battery holder. Loose batteries can cause the faucet to operate erratically. Sept 24, 2020

Sensors Not Working - Moen Solutions

https://solutions.moen.com > Article_Library > Sensors_N...
A
10/21/2022 8:00:45 AM • Moen Plumbing • Answered on Oct 21, 2022
2helpful
1answer

Kohler single lever kitchen faucet,no hot water

no its somthing in water filter rust or dirt in line.take apart and drain line. thank you for useing fixya please rate me
10/3/2022 10:45:07 PM • Kohler... • Answered on Oct 03, 2022
0helpful
1answer

Grundfos Scala 2 Late Stop

It can only be three different things you've got air in the line or your pressure tank which is called the exterol tank could be losing pressure you might need a new air gauge pressure gauge on your tank or number three you have a leaky faucet somewhere or like I said air in the line if I had more details I could tell you exactly what it was
9/30/2022 9:39:55 AM • Grundfos... • Answered on Sep 30, 2022
1helpful
2answers

Have Taboret K 8201-4 bathroom faucet with T handles.

Question edited to fix the typos. Always worrying when they discontinue lines, and it makes you wonder why? https://www.us.kohler.com/us/taboret-centerset-bathroom-sink-faucet-with-lever-handles/productDetail/product:420060/420060.htm I normally find that they use steel screws and they stick. Make some sort of a dam around the screw with stout polythene like Ziploc bag and electrical tape to seal the base. Then squirt penetrating oil or WD40 in there to cover the screw head. Top it up a couple of times a day and do that for two days. That should loosen it up and get the oil down the threads. Often it is just easier to buy a new set.
9/23/2022 12:45:42 PM • Kohler Plumbing • Answered on Sep 23, 2022
33helpful
4answers

Indicator light for Brita filter not working

I see this alot when I do installs...contact the Brita tech support
1-800-24-BRITA (US)
9/20/2022 10:46:01 AM • Plumbing • Answered on Sep 20, 2022
2helpful
4answers

Grundfos MQ pump starts every 15 seconds

Pressure is bleeding back through the pump or system to the tank or well or where ever the water is coming from. Should be some sort of one way valve to keep water from going back to the source, mounted somewhere so that once pressure is pumped up, it will hold that pressure in the part of the system that has the pressure switch that controls the pump.That or you have a leak where you can't see it. (Actually you do, it is just internal and not leaking outside the pipes!)
9/1/2022 9:24:14 PM • Grundfos Pumps... • Answered on Sep 01, 2022
0helpful
2answers

Reverse Osmosis air gap faucet leaking.

this is an easy fix and quite common. I found that removing the drain line where saddle is mounted and clean it from the inside. A common leaking problem in most taps is the "air gap leak." It occurs when water leaks through the hole on an air gap faucet. An air gap is a vital component of the reverse osmosis system. It prevents the back flow of water into the reverse osmosis unit. Instead, the air gap directs the excess water into the drain lines. When a lot of debris accumulates in the drain line, it clogs up, creating back pressure that forces water to flow out through the air gap. Unfortunately, the back flow can flood your countertop. To fix this problem, remove all the debris accumulated in your drain line to allow water to flow smoothly. You can use a wire brush or a pipe cleaner to clean out the drain line, starting from the end connected to the system's drain saddle. You should also clean the system's drain saddle and ensure that it's properly aligned with the drain line. That's because the drain saddles can sometimes shift away from the drain lines. To avoid air gap leaks completely, treat the drain line regularly using a natural cleaner that can dissolve the solids blocking it. Also, avoid flushing big chunks of food down the drain line.
8/28/2022 4:39:59 PM • Plumbing • Answered on Aug 28, 2022
7helpful
3answers

Flotec 42 gallon water tank - short cycling and

These holding tanks are pre charged with air which in turn pressurizes the water. The tank has a bladder and an air valve on top. The pre charge ,over time, loses pressure, and the tank has to be pressurized again.
  • The well pump needs to be turned off.
  • The water has to be drained from the tank
  • Air is put into the tank from the air valve on top of the tank, and is measured with a tire air gauge.
  • The pre charge pressure is set to two psi below the pump cut in pressure.
  • In other words if your pump kicks on at 30 psi, the pre charge pressure is set at 28 psi. If the pump kicks in at 20 psi, the pre charge is set at 18psi, etc.
  • After you pressurize the tank, turn water back on.
  • If water comes out of air valve on top of tank, then the bladder is ruptured and you need a new tank.
  • Hope this helps!
8/27/2022 11:47:31 PM • Flotec Corrosion... • Answered on Aug 27, 2022
0helpful
2answers

My GE 153 will fill and drain but will not spin or agitat

The main motor is not running. I suspect water damage to the controller, probably corrosion on the motor wiring terminals. Also check the motor itself for signs of corrosion, especially at the terminals and the centrifugal switch housing at the end opposite the pulley..
8/7/2022 5:44:43 AM • Plumbing • Answered on Aug 07, 2022
0helpful
3answers

I have a star water sump pump and it is just

Assuming nothing is jamming the impellor it sounds like a capacitor fault. Sometimes these are built in to the pump which can be a pain to get to. Normally near the handle where the cable enters the pump. If your lucky it will be mounted in a control box. Small cylindrical item about 3 inches long. Prob around 10, 12 or 16 micro farad. Easy to change, 2 wires not essential which way round
8/7/2022 5:41:43 AM • Star Water... • Answered on Aug 07, 2022
0helpful
1answer

My Grundfos PM2 pump is constantly stopping and starting

possibly overheating due to bad motor when it cools down it comes back on
8/7/2022 5:39:01 AM • Grundfos... • Answered on Aug 07, 2022
0helpful
1answer

Can;t find set screw tto remove on moen single handle kitchen faucet. it;s not a cap cover that pulls off.

moen dot com go there the manual for it is there, all mine are. some are very tricky, RTM read the manual costs ZERO to read. and is best for sure if tools are needed, or other odd things. no 2 valves on earth are the same zillions, models unless are.
8/6/2022 3:51:31 PM • Moen Plumbing • Answered on Aug 06, 2022
0helpful
1answer

Wiring diagram for goulds j5 shallow well jet pump start switch

https://www.youtube.com/watch?v=ghOML9Ap1ls https://www.facebook.com/GouldsWaterTechnology/videos/how-to-change-voltage-on-a-jet-pump-motor/512687202912227/
8/4/2022 11:46:55 AM • Jet Plumbing • Answered on Aug 04, 2022
Not finding what you are looking for?
Plumbing Logo

8,751 questions posted

Ask a Question

Usually answered in minutes!

Top Plumbing Experts

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66835 Answers

Are you a Plumbing Expert? Answer questions, earn points and help others

Answer questions