heater and just recently installed now...what keeps popping up on the screen is an AO error saying something about the blower prover. anyone can direct me to what that is? on the back of the fan there
Question about H Series Pool & Spa Heater 400k Btu Propane Gas Milivolt Ignition H400p1
heater to work again, with out spending alot of money again. This error is produced when the blower prover switch does not close after the blower starts, the control will stop the ignition and go into
Question about H Series Pool & Spa Heater 400k Btu Propane Gas Milivolt Ignition H400p1
...HEATER The AO mindicates an open prover switch ,, here from Hawward site . If the blower prover switch opens unexpectedly during operation the control will shut down and attempt to re-light. If the ...
Question about H Series Pool & Spa Heater 400k Btu Propane Gas Milivolt Ignition H400p1
...blower prover switch does not close after the blower starts, the control will stop the ignition and go into lockout. Automatic reset is immediate after the blower prover switch closes. If you keep ...
Question about A.O. SMITH Cyclone XHE Natural Gas Commercial Water Heater BTH-120
...hot water at any sinks. The fan is not operating -- when this conditon exists, the unit will not fire up. Here's a link to the manual. The unit needs servicing. ...
Question about H Series Electronic Ignition 250,000 Btu Pool Heater H250ped2
blower prover switch does notclose after the blower starts the control will stop the ignition trial go intolockout. The blower will continue to run. Automatic reset is immediate afterthe switch closes
Question about H250FDN Low NOx Natural Gas Pool or Spa Heater
...heater has been off all summer and upon trying to ignite it , the digital display reads 'AC" indicating that the prover switch is closed when expected open error....what do i do? Thank ...
Question about 50 Gallon FVR NATGAS Water Heater 6YR 22V50F1
hot water heater The hot watr heater quit working. When you turn it on the red light flashes for a while and the powervent motor makes a quiet buzzing but does not come on. After a while the red light
Question about M1TW40S6FBN 40 GALLON RESIDENTIAL POWER VENT
water-heater.html#intellivent Plug blower in separately and see if blower motor functions. This will eliminate blower as suspect. Have plumber check wiring, test and replace blower temperature switch,
Question about M1TW40S6FBN 40 GALLON RESIDENTIAL POWER VENT
...blower prover switch opens during the postpurge cycle (heater is not fir- ing) the control will display the error code. The post-purge cycle will be com- pleted once the blower prover switch close ...