...td sensor location we are getting an sc385 error from our aficio color 6513 and from what i have discovered, the id sensor and the td sensor may need to be cleaned. where is the id sensor located? is ...
...TD sensor information (K) - Timing - When communicating with TD sensors, during printing process, or process control self-check - Condition - TD sensor output exceeds 4.5V or drops below 0.5V. ? Poor ...
Question about Aficio 2022 All-In-One Laser Printer
...TD SENSOR FAULT, CHANGED WITH ANOTHER 2ND HAND UNIT I KNOW WAS WORKING FINE BUT DRUM WAS WORN ON EDGES, STILL SAME FAULT? THEIR ARE NO SEAL BEEN LEFT IN UNITS. PLEASE HELP. ? Someone forgot to remove ...
Question about Aficio 2022 All-In-One Laser Printer
...TD sensor, you change the develop and Performs the TD sensor initial setting. 1) Press the following keys in sequence. Total clear yellow key, 1 0 7 and Hold the clear stop key (orange key) for more ...
...TD sensor on the developing unit and the I.D sensor above the drum by default. These are low cost parts and easy to change. (The TD sensor on this model have been known to fluctuate back and forth by ...
...TD sensor error test value abnormal the TD sensor output voltage is less than 0.5v or more than 5.0v after 10 consecutive times during copying the possible cause willbe TD sensor defective,TD sensor ...
...TD sensor is reading an abnormal value, this could happen if no toner is getting into the developer unit or it could be a bad TD connection or TD failure. Would suggest checking to see if the toner ...
...TD sensor defective TD sensor not connected or disconnected damage Poor connection between the TD sensor and IO board IO board defective Toner supply defective * Insufficient toner in developing ...
Question about Aficio 2016 Black and White Copier
...if the toner motor is rotating, also check if the buttom of the toner unit is designed to fit the toner motor. finally check the td sensor . this may be the major cuase of this problem. good
Question about Aficio 2016 Black and White Copier
TD sensor error black PCU possible cause: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor
Usually answered in minutes!
2,817 Questions
2,244 Questions
2,162 Questions
2,149 Questions
1,912 Questions