Split System Air Conditioner Our air conditioner was displaying a C6 error, now it is displaying a C5. There's nothing in the manual about this...could you please advise what the problem is? Thank you
Question about 24KS62R Cool Mini Split Air Conditioner
...also have a capacitor sometimes they share a capacitor called a dual run capacitor. the markings on this cap are. herm = compressor, fan = condenser fan motor, and commune = power in. hope this
Question about 24KS62R Cool Mini Split Air Conditioner
...air If the fan just hums and if you spin the fan and it runs, check out the capacitor, it is bad. Most condensing units have a split capacitor, for the hermedic unit and the fan. If the compressor ...
Question about Mr. Slim MXZ30TN Air Conditioner
...split outdoor unit fan. Outdoor unit fan will not start. Diag LED's say bad fan motor. Replaced motor and have the same codes. Check the capacitor. Rating must be within 90% of rated microfarads. If ...
Question about Mr. Slim MXZ30TN Air Conditioner
...split system air conditioner, and what does it look like This capacitor is usually located where the line voltage goes into the unit. There can be two capacitors or one. This is probably a dual ...
Question about Mr. Slim MXZ30TN Air Conditioner
What size dual capacitor does a Lennox 3 ton heat pump require for model #12HPB36-4P? what is the ideal rating of capacitor for 3 tonner split type air conditioner, 220VAC?
Question about Mr. Slim MXZ30TN Air Conditioner
...split system air conditioner that stopped working. The dual run capacitor was bulged and leaking so we replaced it. The unit still won't come on. What else should we check? your phone book for a ...
...split capacitor) motor, then it will have a run capacitor wired in series with the start winding, and this capacitor never comes out of the circuit, providing greater running efficiency. This ...
...split, the old capacitor had 3 contact points, the new one has got only 2? Can anyone help out? Yes, your old one was probably a dual capacitor. The middle terminal was common to the compressor ...
Question about LS-L1210CL Mini Split Air Conditioner
...motor not working What is power to unit and what type of unit is is ? Split system needs 24v to Condensor . And a dual pack need a call from tstat also. Check if u have a dual capacitor wired
Usually answered in minutes!