Rinnai Gas Heater (approximately 30 years old) still working well, but we had to turn off the gas, and now cannot turn it on again. We have two buttons, one below the other, one is red and say On, the
...gas cylinder but the heater will only stay alight with the ignition switch kept pushed in. Does this unit have a thermocoupling? If so replace it. (6 bucks) It is the units flame sensor and they ...
Question about RHFE-1004FA 38,400 BTU Energy Saver Ductless Heater - LP Gas
...rinnai energysaver 1000ft I havent used it before - we just bought this house with it instaled. when I turn it on the fan goes for a minute or so, the ignition fires and the red light turns on, then ...
...rinnai cosy glow 650 when i push the start button it glows up but soon as i let the button go it stops glowing The cosyglow heaters have 2 thermocouples in series to sense flame and keep the thing ...
Question about Vent Free Gas Heater/: 14,000 BTU Vent Free Heater
...works normal with no problems. i just have a safety issue because i now have an open flame. any idea? My pilot light on a rinnai gas fireplace wont stay lite when i take my finger off any
Question about RHFE-1004FA 38,400 BTU Energy Saver Ductless Heater - LP Gas
what does the red light mean on rinnai energysaver 1001f? Means the burner is alight. Follow this link for a copy of the custmers manual http://www.houseneeds.com/shop/manuals/rhfe1004fa.pdf Cheers
...gas supply to keep it alight. This will happen after it has lit, maybe erratically with the occasional error code 11 if you try and re-light immeadiately. rinnai 516 lights goes to high speed heats ...
Question about RHFE-1004FA 38,400 BTU Energy Saver Ductless Heater - LP Gas
...see an arcing, this is the igniter. With a power outage there is no telling what may have happened. With only limited knowledge of a gas heater you should call a Rinnai service guy. Good luck, ...
Question about RHFE-1004FA 38,400 BTU Energy Saver Ductless Heater - LP Gas
rinnai gas log heater (royale) keeps cutting out. now it wont stay on at all. the ignition is fine, the gas flow seems fine and the fan works fine. we vacuum the dust out regularly When you say "it ...
Question about RHFE-1004FA 38,400 BTU Energy Saver Ductless Heater - LP Gas
gas heater stay alight The heater will not stay lit after pressing down ignition button Some heaters have to be "warmed up" by holding the button down for approx. 30 seconds after it lights. These are