Questions & Answers for: reddy heater firing cutting

Question about Heater-30-55,000 BTU Variable

2 Answers

reddy heater won't stay on I have a 35,000 btu reddy heater that will fire up if I push the button, but it will only push heater for maybe 15 seconds or so and then shut down. If I push the button, it

Ad

Question about Heater-170,000 BTU Kerosene Deluxe

2 Answers

reddy heater model# 016920475 heater fired first time after sitting for maybe a year. I cut it off after about 15 minutes. after aprox.20 minutes I tried to restart and it would not. The ignition lite

Ad

Question about Heater-30-55,000 BTU Variable

1 Answer

...reddy model r55 and it will only start at times if you take the top cover off then when it fires up you can put the cover back on and it will be fine. Any suggestions? Check that the fan is clean and ...

Question about Heater-30-55,000 BTU Variable

1 Answer

...REDDY HEATER 5500 Hi, Here are a couple of tips that I wrote that tell you how to troubleshoot aTorpedo or Reddy heater... Reddy Heater - Troubleshooting Torpedo Heaters Torpedo Heater Pump Pressure ...

Question about Heater-30-55,000 BTU Variable

2 Answers

...this unit does nothing. TNX Steve Basicly I need the repair shops near Albany, Ga. I E-mailed reddy but have not heard from them I had the same problem and removed the heat adjusting panel and ...

Question about Heater-30-55,000 BTU Variable

1 Answer

what makes the heater start up then cuts off after about 5 seconds with a little of kersone running out of the front of it This is normal. It has a time limit to fire off. The heater will cut off if ...

Question about Heater-30-55,000 BTU Variable

1 Answer

reddy heater getting fule,air&fire runs 30 sconds cuts off does not light Things that can cause this symptom A dirty fuel nozzle a dirty photo cell / an inproperly positioned photocell or ...

Question about Kerosene Garage Shop Heaters - All Pro PK115T Forced Air Kerosene Space Heater

1 Answer

...Here are a couple of tips that I wrote that tell you how to troubleshoot a Torpedo or Reddy heater... Reddy Heater - Troubleshooting Torpedo Heaters Torpedo Heater Pump Pressure Adjustment ...

...Reddy heater 30-55,000 btu.. When lighting it I press in the initer for the recomended time but after I release it the flame goes out.. Can you tell me why?. It seems as if you are not holding the ...

Reddy heater multifuel forced air heater will start and run 5 minutes then shut down with a big puff of smoke. if I cut the power then reconect if will fire up run 5 minutes and shut down again Is ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!