Question about 1-HP Cast Iron Shallow Well Jet Pump PPSWJ100
...Utilitech 1hp shallow well jet pump which turns off and on rapidly while using water. I have 25 psi in the air tank. I replaced the pressure switch and still have problems. I turned off pump and ...
Question about 1-HP Cast Iron Shallow Well Jet Pump PPSWJ100
I have a utilitech convertable pump. It is used as a shallow well pump at the moment. It worked fine untill last week, the hot water tank went bad and we replaced the tank and all the above ground ...
Question about 3/4-HP 15 GPM Shallow Well Jet Pump 3/4-JET
I have a Utilitech 3/4 HP jet shallow well pump #0003134. On start up, it hums a long! time before turning, sometimes tripping the 15 AMP breaker. Anything I can do? It's wired for 115V. Try ...
Question about 3/4-HP 15 GPM Shallow Well Jet Pump 3/4-JET
I lost my instructions for my Utilitech #0357930 timer. I cannot get it to work; I can set it to start but not stop. Just need some directions. Buttons on it are On, Off, Day, Hour, Min, Enter, Pro I ...
Question about 3/4-HP 15 GPM Shallow Well Jet Pump 3/4-JET
utilitech pro submersible pump has good electrical connection but pump won't start I'm getting 120v per leg below the splice on the pump side but the motor won't run. The breaker doesn't switch off, ...
pump does not hold pressure pump cuts on at 20psi when water is running but the pressure keep dropping and the water stop decause the pressure is gone. Sounds line a problem with the water source. A ...
Question about 0.33-HP Thermoplastic Submersible Utility Pump PPSU25
Why won't my Utilitech dusk to dawn light work If you know the bulb is good, try changing the photocell. Why is it half of the problems on this site are Utilitech? I think I see a pattern.
Question about 0.33-HP Thermoplastic Submersible Utility Pump PPSU25
just installed a utilitech 2hp sprinkler pump and can only get 10psi out of it what could be the problem HI there. . Is it a new pump?
Question about 0.33-HP Thermoplastic Submersible Utility Pump PPSU25
My Utilitech 1 hp well pump turns on and off fast while usng water.There is about 28 lbs.pressure in tank. I saw same problem that someone else had but could not pull up the answer.Help & thanks. ...
Question about 0.33-HP Thermoplastic Submersible Utility Pump PPSU25
Utilitech heater may have a power problem or a thermostat problem. The power cable should be inspected for wear or damage, and the power outlet should be tested to ensure that it is operating properly