...power supply or main motor board E202 Scan problem. Motor sensor E210 Lens drive problem E220 Exposure lamp E240 Main board or composite power supply E260 Main board, power supply cooling fan or ...
Question about (6981A002AA) for imagerunner 2200, 2800, 3300 Print Server
power supply PCB is faulty. The DC controller PCB is faulty. Caution To clear the error, execute the following in service move: COPIER>FUNCTION>CLEAR>ERR. Action 1. Fixing film unit Check the
Question about (6981A002AA) for imagerunner 2200, 2800, 3300 Print Server
...power supply PCB, or the DC controller PCB is faulty. NOTE: You can reset the error by performing the following in service mode: COPIER>FUNCTION>CLEAR>ERR. CONNECTOR FIX: Make sure that the ...
Question about imageRUNNER 3300 All-In-One Laser Printer
...power supply PCB is faulty. The DC controller PCB is faulty. Caution: To reset the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR. Action: 1. Connector Is the ...
Question about WorkCenter 4150 Black and White Copier
power supply unit 2. If necessary, install a new power supply unit 2, PL 1.10 Item 4. 4. Switch off the machine. Remove the fuser assembly. Check that the thermistors, PL 10.25 Item 9 are clean and in
Question about CANNON IR 3530 COPIER FOR 220 VOLTS ONLY
...power supply. While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply. While startup ...
Question about CANNON IR 3530 COPIER FOR 220 VOLTS ONLY
...power supply PCB is faulty. The DC controller PCB is faulty. Caution To clear the error, execute the following in service move: COPIER>FUNCTION>CLEAR>ERR. Remedy Check the interval between ...
Question about CANNON IR 3530 COPIER FOR 220 VOLTS ONLY
...power supply. While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply. While startup ...
Question about CANNON IR 3530 COPIER FOR 220 VOLTS ONLY
...power supply PCB is faulty. The DC controller PCB is faulty. To reset the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR. Remedy:1. Connector Is the connector of the ...
Question about CANNON IR 3530 COPIER FOR 220 VOLTS ONLY
...FIX-E=310°C for the sub thermistor. 2. Main power supply PCB, DC controller PCB Try replacing the main power supply PCB. Is the problem corrected? YES: End. NO: Replace the DC controller