...pilot assembly a little bit to get it more into the burner flame (not too much, since there is only so much availble slop in the assembly without bending parts), and the burner stayed lit longer, but ...
Question about Honeywell Heating & Cooling
...pilot but wont light the burner. How do I fix? You need to remove the flame sensor on the far left hand of the burner. In has a single wire going to it in between the jets. I believe it is a white ...
...light my pilot Are you sure it has a pilot light? Some of the newer heating systems do not have a pilot light but a glow bar ignition. Lets open up the door and I need you to look for the gas valve. ...
Question about Programmable Thermostat Heater
...light and I just replaced to batteries on the thermostate. It could be a few things, dirty pilot assembly, dirty or bad flame sensor or a bad gas valve or loose wire on the gas valve. Watch the flame ...
...light and then turn off 5-10 seconds later. It will do this three or four times and then shut down. I thought perhaps the damper is hanging up and not regulating exhaust temp. To my surprise I find ...
...pilot assembly to any close screw to boost the (pilot on) signal.Also if the valve has been sitting for a while give a tap once during (pilot on) to make sure the diaphram is just not hung up.I would ...
Question about Programmable Thermostat Heater
...pilot light as the main problem. it may need to be cleaned. then look at flame rod position. remove gas tube from bottom of pilot assemble and a small thimble looking thing should come out it has a ...
pilot light goes out when i release the button statos light not blinking and pilot light goes out when i release button Question posted under Reliance gas water heater.Add comment for different ...
pilot light not being lit might have clogged orifice in the ignitor assembly a quick check would be to remove the pilot line depress gas valve if u hear or smell gas it's the orifice remove and clear ...
...pilot continued to not light. After more troubleshooting, including checking the ventilation, I determined the gas control valve and thermostat needed replaced. I installed a Rheem sp14270g gas ...