...pilot goes out, try one more time. If it goes out again after releasing the button your thermocouple is bad and must be replaced. The thermocouple generates a millivolt electrical current that hold ...
...pilot goes out after you turn on the timer or goes out by itself. If it goes out by itself (without turning on the timer) then you need to make sure your thermocoupler and overall pilot generator ...
...off> have replaced thermocouple and pilot lights instantly but after unit runs and cycles off pilot goes out. Flame from pilot appears to be too large had same problem; its in the gas valve ...
...pilot goes out, but then it also goes out in the same 3 to 5 minute span. I can imeadiately relight the pilot if I push down the lighting button but it will not stay lit untill the unit cools again. ...
pilot goes out you need to replace the entire temp control if pilot goes out as soon as you release the pilot button you need to replace the thermo couple little copper wire the goes from regulator to
...pilot goes out? theres a black wire that goes from the thermostat to were the pilot switch is.. and when i wiggle the wire the pilot goes out and somtimes it will stay on but can not get gas to the ...
Question about IFS40 Deep Fryer
pilot goes out flame drops down and goes out Try cleaning the pilot out sounds like flame is too small and when main burne rlights it takes gas away from pilot .Clean pilot try blowing it out with can
Question about Unvented Gas Space Heater
...pilot lite goes out also heater lites pilot lites but when heater reaches the desired temp and go off the pilot goes out also I would start with cleaning the Pilot ODS Assembly and also reseating the ...
Question about Worcester Spark Electrode 87161421190 Fits 230/240 Rsf Highflow 400 Rsf
...pilot goes out pilot will light ok when you hold your finger doen when i release finger it goes out Your thermo couple is bad. Thats the copper tube that goes from the gas valve to the pilot. It ...
Question about Worcester Spark Electrode 87161421190 Fits 230/240 Rsf Highflow 400 Rsf
...pilot lite goes out - They got rid of pilot stoves because the pilot was always lit and using gas. And without a lit pilot no way you can get the burner to ignite unless you use a match, assuming you ...