Questions & Answers for: mastercraft water pump

...water from well The pump is 1/2 hp Mastercraft jetpump With no leaks in line and assuming the jet is not embedded in debris at bottom of well, try priming the pump again and getting all the air

Ad

...Water Jet pump will not start I have a Mastercraft 1/2 hp shallow well pump that will not start. The cord is fine,I put a tester on the cord and Im getting power when touching the pressure switch ...

Ad

Question about Waterway Spa Pump 3/4 HP 115v

1 Answer

water is still running.Type Mastercraft 3/4 hp. Is there a surge or reservoir tank in the system? Or the pressure switch may have to be adjusted. Write back with more information. Gary if all other ok

mastercraft 1/2 hp jet pump not shutting off - normally shuts off at 30psi, continually runs, have to kill power to shut off. Just hooked up pump for the spring. It feeds water from a cistern to ...

Question about Waterway Spa Pump 3/4 HP 115v

1 Answer

Mastercraft 6.5 Gal.3/4 hp does not hold pressure My pump only comes on as I need water. No reserve? The pump goes on/off/on/off when the toilet is flushed. You run any tap while the toilet is being ...

...mastercraft jet pump ran dry and will not pump what am I looking for to fix it? Hi Nick: Just for fun, try priming it. Remove the Pupe plug with the square head, fill it with water, screw the plug ...

1/2 hp mastercraft water pump,wires disconnected in motor behind plate. Which wires go to which leads? schematic on side of motor low voltage and high voltage wiring

...mastercraft water pump model 312242 Fixya is unable to suggest sources for Mastercraft parts. Above answer is talking about an automotive water pump. This is a jet pump for home cottage water supply. ...

...mastercraft 3/4 water pump and were doing laundry and the pump lost prime and stopped pumping, what could cause this. Thanks. charlie no water in the supply line for the pump empty tank or if bore ...

Question about Waterway Spa Pump 3/4 HP 115v

1 Answer

Mastercraft 3/4 HP shallow well pump fault Pump now runs for 10 seconds every two minutes then shuts of and keeps repeating. No leaks found and no water devices turned on check and test pressure ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Plumbing Experts

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66967 Answers

Are you a Plumbing Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...