Questions & Answers for: Goodman low flame

Question about GMS80453ANA Open Flame Mid-Size Heater

1 Answer

Blower speed too fast Goodman GMS80453ANBC. I think the blower is on med or high. Need low speed. The furnace should be a 3 or 4 speed motor in it. On the circuit board there are places maked heat and

Ad

Question about GMS80453ANA Open Flame Mid-Size Heater

1 Answer

...flame sense signal drops too low the furnace will not sense flame and will lock out. The flame sensor should be carefully cleaned by a qualified servicer using emery cloth or steel wool. Following ...

Ad

Question about GMS80904BNA Open Flame Mid-Size Heater

1 Answer

low flame signal when the heater kicks on the flame only last seconds then it turns off by its self then it returns on and off and continues to do so until it finally stays on this is not normal and ...

Question about GMS90703BXA Heater

1 Answer

low flame signal my goodman heater struggles to turn on and 7 flashing lights come witch indicate low flame signal,what does this mean and how do i fix it? There is a small probe that is located ...

Question about GMS90703BXA Heater

1 Answer

...low volume needed for a pilot flame. I bet that when you removed the old pilot tubing this oriface fell on the floor and rolled under the furnace. Find it, clean it and reinsert it. You will be fine. ...

Question about GDS80904BNA Open Flame Heater

1 Answer

...flame. That's where it shuts off after a second. could be the circuit board burned up, check the back to see any dark burnt areas,(this happens alot with this model, they have even started making the ...

Question about GDS80904BNA Open Flame Heater

1 Answer

...low heat. have done all this and as soon as the fan kicks on the flames go out. If the flame lights all the burners within 2 seconds but does not stay on, you may need to clean the flame rod found at ...

Question about GDS80904BNA Open Flame Heater

1 Answer

...low flame There is a sensor located on either the far right or far left of the burner tray. It will be in the path of the flame on the last burner that ignites. Take a scrub pad and clean the rod. ...

low flame sense microamp signal. This could happen with a coated flame sensor or a lazy flame from poor gas pressure. Turn off the power and adjust the gas pressure according to the information on the

Question about GMS80903BNA Heater

3 Answers

...burners , lack of clean air to burn , blocked or dirty air ports lack of servicing pet hairs sucked it to burners . gas presssure to low or high , all will give a yellow flame which will cause

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Goodman Heating and Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...