Questions & Answers for: light blinks twice furnace

Question about Heating & Cooling

2 Answers

...light, which reads OK, will blink twice then stop, blink twice then stop over and over. The Flame light will not go on. Any ideas what could be wrong. Any help is greatly appreciated. Thank you. Take ...

Ad

Question about Goodman Heating & Cooling

1 Answer

...twice each time then gives single flashing light. when I switch upstairs control from 'auto' to 'on' air circulates, but does not get warm. Check the inside door to see what the blinking light means. ...

Ad

...light blinking twice. I can not figure this one out. Thanks for any advise. I would try to check your return air first, making sure there is no blockage and that your air filters are clean. It almost ...

Question about Programmable Thermostat Heater

1 Answer

...is cut off. The led light blinks twice.Any ideas? check out your fan control could be dusty at the back remove it and clean it also check air fiter is clean , or tthe fan conrtol could need ...

Question about GDS80904BNA Open Flame Heater

1 Answer

...light won't stay solid and blinks. the furnace won't cycle more than once or twice before it just won't go and it is not warming up to what the thermostat is set on. we have to flip the actual switch ...

...light blinks twice until the 2nd stage turns off. It reaches it's temp and shuts off. Why does it blink? I have a rheem classic 80+ two stage. When the 2nd stage kicks in on the cycle the green ...

Question about Gas Furnace 60000 Btu 95% Afue. Rgrc Model

1 Answer

...a gas furnace. it want fire up due to blinking red light blinks twice. says pressure switch open while inducer motor is on. what do I need to do? you need to replace the pressure switch it is

Question about Gas Furnace 60000 Btu 95% Afue. Rgrc Model

1 Answer

...starts, but it wont ignite unless it gets turned off and on again. Green light inside blinks twice. Could be that your vacuum switch is stuck closed it has to start open then close for safety ...

Question about Gas Furnace 60000 Btu 95% Afue. Rgrc Model

1 Answer

light blinks twice The induced draft motor you describe has a pressure switch proves the induced draft motor is running, it is about 4 inches across and silver and flat and round, it has 2 wires and a

Question about Gas Furnace 60000 Btu 95% Afue. Rgrc Model

1 Answer

...light blinking twice 1/2 second then pause about 2 seconds, repeat flashing could it be thermocoupler or ignitor? The information you have given is a code. You can look in the back of the owner's ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...