Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
...but when it gets to the start pin it does not turn pump on and the time stops there..... it is an intermatic timer the timer motor brushes are worn ...
Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
My T12404R's flywheel has stopped turning. it sounds like it is on and manual controls work but the clock is not turning. I determined that the electric motors had stopped funtioning and ordered ...
Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
Intermatic Pool timer will not turn off... I have to shut off the pool pump at the breaker... Any suggestions on what the problem might be? If the pool pump timer is not working, first look and see if
Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
...to turn off pool pump. After the restoring power the pump stopped working. I tried to turn on the intermatic timer manually, but nothing happens. Could it be the timer,motor,capacitor...? Need help ...
Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
...intermatic-t12404r-control-center-w220v-dual-timer-wo-breakers-p-543.html BH electric shows the T10000 series for $178 http://www.beverlyhillselectric.com/t12404r.html Add a comment if you need help ...
Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
my intermatic pool tmer will not set time or let me auto. turn to on so I can't filter or backwash pool Problem points to electric power. 1) For best possible free answer, please add a comment and ...
Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
...posted under T104 which is 240Volt timer and uses WG1573 clock motor. http://waterheatertimer.org/Intermatic-trippers-and-parts.html#T100 To test voltage, test across terminals 1 and 3 for
Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
I have a Intermatic T104R 250 VAC to pump. Just purchased new Raypak 266K digital, electronic water heater. Want to attach it to the above timer. Will it work or need an upgrade or a new timer so can ...
Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
...Intermatic T12404R control center has 2 timers. Each timer is set same way. Timer must be reset after power outage. If time dial is not rotating correctly or is sticking at the tripper, then the ...
Question about Timer T12404R Pool & Spa Controls with One T104M201 and T104M
Can an intermatic pool timer be switched out with an intermatic hot water heater timer both look identical both are timers and the possible difference is the current rating for the unit the rating for