thermopile.it could be the valve but i would replace the thermopile first,its a cheap part.contact imperial for it.its also easy to replace.also make sure all wire connections are good,clean and tight
Imperial Fryer Pilot Won't Light IFS50 The gas valve, thermopile, and high limit are new. This unit worked fine for about 1 month. Maybe bad thermopile again???? For sure if you got gas to the ...
pilot light will not stay lit use a torch to simulate pilot flame and read milivolt. if ok then make sure pilot flame is fully contacting thermopile. also make sure thermopile wiring connections are ...
...Imperial fryers I have worked on takes the thermopile with the wire leads. Suggest you contact a repair company that can test the thermopile. Is should generate at a minimum 500 mv dc. If it doesn't ...
what would casue the pilot light to go out when the burners shut down 1.bad thermopile, 2. insufficient gas pressure, 3. thermopile not receiving enough heat from the pilot flame.
where is thermopile located? Hi there. The thermopile is the cylindrical shape piece of metal standing behind the pilot assembly. The pilot assembly is the one that we light up with igniter or lighter
thermopile on Imperial IFS-40 deep fryer The pilot light works when I turn up the gas I can hear it click but it doesn't kick in. I've seen other post saying to test the thermopile but
Question about IFS40 Deep Fryer
imperial fryer. Pilot is on but main burners don't ignite. Pilot looks normal & thermostat clicks when turned Number 5 is your thermopile/pilot generator. It is a pilot generator that does
ifst-25 will not stay lit Could the thermopile be going bad? Clean pilot check thermopile should show 600millevolts
Question about IFS-40 - Gas Deep Fryer - 40 Lb - Tube Type - 15-1/2" Wide
need a wiring diagram for ifs 40 imperial fryer replaced thermopile need complete wiring diagram http://manuals.kdfsi.com/Imperial/fryer_diagrams.pdf