Question about Laars Lite 2 Heaters: 250,000BTU MV Heater
...ignition module that will blink to tell you what the failure is if is is a newer on. When you turn power on to laars light 2 the inducer motor should come on then a pressure switch should send 24volt ...
...ignition. Need help on how to test ignitorb You can light the pilot with a B.B.Q. lighter. Nottoohandy. Backwash you filter, make sure it's really clean. If that doesn't work it could be the pressure ...
Question about Laars Lite 2 Pool Heater 250,000 Btu / Natural Gas
...switch it on, I get flames for 2 seconds and then it shuts off. I tested the rollout and the pressure switches on front, and they are ok. Is it the ignition system that's failing. It uses a Fenwal ...
Question about Laars Lite 2 Pool Heater 250,000 Btu / Natural Gas
...the old manual control panal not digital. Will not lite, or start ignition process. Water flow is good, natural gas is flowing. Is there a reset for the ignition system? could be the pressure
Question about Laars Lite 2 Pool Heater 250,000 Btu / Natural Gas
...switch it on, I get flames for 2 seconds and then it shuts off. I tested the rollout and the pressure switches on front, and they are ok. Is it the ignition system that's failing. It uses a Fenwal ...
Question about Laars Lite 2 Pool Heater 325,000 Btu / Natural Gas
...Ignition switch does NOT work. Trying a butane torch lighter. there is no mirrow to see as per manual. d You may need to adjust the pressure switch. It is in this manual and you may find more tips to ...
Question about Laars Lite 2 Pool Heater 250,000 Btu / Propane Gas
...ignition Possibly a flow switch not closed, or a limit switch open. May even be the pilot generator not producing enough mili-volts to operate the gas valve. Safest way is to have it serviced by a ...
Question about Laars Lite 2 Pool Heater 250,000 Btu / Natural Gas
ignition switch. when I turn the switch to the "on" position, nothing happens. if the unit is used you might have to removed the burner and clean the pilot sometimes rust built in the hole and need to
Question about Laars Lite 2 Pool Heater 250,000 Btu / Natural Gas
...switch off and right back on it will run agin for 10 minutes and shut off. It sounds like your pool heater might have a defective controller (the part, not you). Check the controller and replace if ...
Question about Laars Lite 2 Pool Heater 250,000 Btu / Natural Gas
Laars Lite 2 Model LD Pool Heater won't start. When turning it on I used to here a a couple of noises, like a tick, tick then it would ignite. I don't here those sounds anymore. Gas is on ...