...heater, and removing the outer 2 PVC reducer connectors. Then you'll have access and sight to the exchanger input (3" pipe?) and should see what I'm talking about. If the plate moves (or isn't tight) ...

Ad

Question about H Series Induced Draft Abg 100,000 Heater

1 Answer

...heater, and removing the outer 2 PVC reducer connectors. Then you'll have access and sight to the exchanger input (3" pipe?) and should see what I'm talking about. If the plate moves (or isn't tight) ...

Ad

Question about H Series Induced Draft Abg 100,000 Heater

1 Answer

heater re fired and the symptoms were back. I just got a call from one of Haywards platinum techs, and he said it sounds like it could be the heat exchanger. He said take the supply hose off, and with

Question about H Series Induced Draft Abg 100,000 Heater

2 Answers

...heater, you will see the loose metal plate. One unit was loose on both ends and the other on the output only. Make sure that it is clean and dry. Mix up some" JB Weld", a high temp two part epoxy and ...

Question about H Series Pool & Spa Heater 400k Btu Propane Gas Milivolt Ignition H400p1

1 Answer

...heater diverter plate moves I rec'd info from John 224 about my Hayward H series 100,000 btu AG heater regarding the diverter plate being broken and causing the water to boil. Is the plate to be ...

Question about 100,000 BTU Pool Heater H100ID1 - Above Ground

3 Answers

...heater Water diverter plate is moving upon inspection. This is making the heater shake and the water boil inside. I have seen posts saying to tach weld or epoxy the plate where it should be. When ...

Question about H Series Induced Draft Abg 100,000 Heater

3 Answers

...heater... a metal clinking noise and the hoses doing a twitch every 5 to 20 seconds. my experience says it is that diverter shield has come loose...disconnect everything. unscrew the in and outlet ...

Question about 100,000 BTU Pool Heater H100ID1 - Above Ground

1 Answer

noise I have the Hayward H100ID1 pool heater and it makes the loud clinking noise and the hoses shake when ever I turn on the heater. Reading the other solutions, I checked the diverter plates from ...

Question about H-series Electronic Gas Pool Heater H300

1 Answer

What dose serive mean check gas pressure if not adequate that heater will not run you might need a bigger gas meter call gas company add all your appliances that use gas there should be plates on all ...

Question about 100,000 BTU Pool Heater H100ID1 - Above Ground

4 Answers

...heater outlet) and jam a 3/8" or so stainless bolt or rod between the heat exchanger exit tubes and the top of the baffle plate. This should hold the plate down and force water flow through the heat ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Hayward Pool and Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...