ELEMENT WHICH IS BEHIND THE LOWER PANEL IN THE FRONT.REMOVE THE PANEL WITH THREE SCREWS ON THE BOTTOM AND TAP DOWN AND OUT AT THE SAME TIME. USE A VOLT OHM METER AND CHECK OHMS ACROSS THE TERMINALS OF
...Heater Element? Suspect Thermister on Lint Duct Assembly? Looking for guidence. it sounds like your heating element is gone bad. there is no heat if they burn out or get corroded I would check the ...
Duet electric dryer that won't heat it runs fine just no heat! If you feel competent enough check the heater element and the thermostats for continuity
Element (located inside heater box) - remove the two leads from the ceramic terminals on the heating element and take a reading across the terminal points. It should read 9 - 13 ohms. Thermal Cut-Out
...element. Seeing how new this model is, do you have warranty? As new as you drier is I kind of doubt you have a broken heater. I think you are looking at a systems control issue. This site may help. ...
...Element is located inside a heater box. The Thermal Cut-Out (TCO) will be located on the outside of the heater box on the end opposite the heating element terminals. The Hi-Limit Thermostat will be ...
Element is located inside a heater box. The Thermal Cut-Out (TCO) will be located on the outside of the heater box on the left hand side on the end opposite the heating element terminals. The Hi-Limit
...heater is poor, this is usually due to a plugged lint filter or restricted vent pipe between the dryer and outside. The second is the heat element itself has gone bad. You can measure it with an ...
Whirlpool Duet Dryer: In any program the Dryer is not producing any hot air. element oir thermostat gone check the heater circuit
...heater element itself and the motor. If there is 120 vac at this point then you know the heater is good and the motor is good because the other 120 vac coming through the thermostats is the control ...