Question about H Series Electronic Ignition 250,000 Btu Pool Heater H250ped2
...Hi I have Hayward H250 Direct spark heater, and it sparks, and I can hear the gas valve energize, but then the display says HF, but there is no flame present? Sounds like it could be the flame
...hayward pool heater "ce" error code on hayward universal gas heater 400kbtu CE= Communication Error between Control Module and Display Interface Assembly 1. Disconnect and then reconnect power to ...
Question about H400fdp Low Nox Propane Swimming Pool Heater ()
Hayward H series pool heater, the display panel won't display anything, when I press mode, there is no light, the heater is running as I can feel the motor, I took the front off but there isn;t ...
Question about H Series Pool & Spa Heater 400k Btu Propane Gas Milivolt Ignition H400p1
Hayward 400 H series pool heater digital LED display not working. Do i just replace or is there something else I should check? if voltage coming from transformer then replace display
Question about H250FDN Low NOx Natural Gas Pool or Spa Heater
hayward pool heater display reading AC my pool heater has been off all summer and upon trying to ignite it , the digital display reads 'AC" indicating that the prover switch is closed ...
Question about H-series Electronic Gas Pool Heater H400
hayward electonic pool heater Numeric display not working? if voltage ok coming in and voltage coming from transformer ok then bad display
Question about Hayward H-Series Electronic ED2 Style Heater Replacement Parts - 4 - Heat Exchanger Assy - 300 - HAXHXA1303
I have a Hayward H 300 heater, I can't adjust the temp, the heater fires and runs fine,the display reads the temp. see if on remote
Question about H Series Millivolt 250,000 Btu Pool Heater H2501
hayward heat display is stuck in standby display buttons will not change standby to spa mode you need to replace either the display board or the main circ board
Question about H Series Millivolt 250,000 Btu Pool Heater H2501
...off the unit and checked for lose wires. The inside of the heater unit is dry. CE error code on Hayward pool heater. CE= Communication Error between Control Module. and Display Interface ...
Question about H Series Millivolt 250,000 Btu Pool Heater H2501
Hayward 250hed pool heater control panel. https://www.troublefreepool.com > ... > Everything Else Jun 1, 2021 - If the keypad/display is not getting DC power from the control board for some reason, it