...wall gas heater non-electric. The thermostat is connected right and mounted on the wall. But, there's a thick black copper wire on the side of the furnace tagged thermostat. I don't know what to do ...
...heater comes on. It runs for 10 to 30 seconds and burner and pilot go out. sounds like a blocked pilot when you turn on the main gas takes the gas away from the pilot and goes out that sounds about ...
Question about 3003622 Ceramic Wall Mounted Panel Heater
...wall heater. All is complete. Pilot is on now. Problem, when I turn the williams theromstat from off position to even slightly on, i hear a click sound and it turns off the pilot. Thermostat has two ...
...wall heater at Sandiego home , a pilot lights ok ,I did change a themostat some time the burner come on , some time turn on thermostat a pilot goes out,please give me some help, thanks, Hi, The ...
Question about 3003622 Ceramic Wall Mounted Panel Heater
Gas wall furnace pilot goes out when burner turns off. 3- year old Williams wall furnace. Worked fine until recently. All is well until burner shuts off, then pilot light goes out too. Replaced ...
Question about Wall Heaters: 50,000 BTU/Hr Monterey Top-Vent Gravity Wall
Pilot goes out when thermostat turned on In gas appliances it is mostly gas line or igniter or valve or dirty nozzle or dirty line or main control beard problems All Gas appliances should be checked ...
...wall heater which is propane. It's a brand new tank recently filled. When the pilot was on, it seemed weak and when I turned the burner on, the flame was weak on the burner and the pilot light went ...
Question about Wall Heaters: 50,000 BTU/Hr Monterey Top-Vent Gravity Wall
...is what the pilot light flame heats up when you turn on the heater. when the thermocouple gets hot it sends a 20 to 60 millivolt signal to the gas valve to activate the gas flow to the main
Question about Wall Heaters: 50,000 BTU/Hr Monterey Top-Vent Gravity Wall
...wall heater keeps shutting off LP gas supply.Pilot stays on,when I turn up the thermostat gas comes on, after a short time, gas supply & pilot shut off with a sharp loud noise Replaced thermocouple ...
Question about Wall Heaters: 30,000 Btu/hr Direct-Vent Furnace Natural Gas with Wall or Cabinet-Mounted Thermostat 3003622
Your gas registered installer should have seen it fully working before he left. https://www.google.com/search?q=Williams+direct+vent+wall+furnace+3003822%2C+pilot+goes+out+when+thermostat+turned+on .
Usually answered in minutes!
2,517 Questions
1,056 Questions
713 Questions
416 Questions
354 Questions