Questions & Answers for: fire alarm panel

Ad

Question about SA302 Dual System Smoke Detector

2 Answers

...alarm. Security/Fire systems that work using phonelines require at type of connection often referred to as "line siezure". This basically means that the phone line must go through the Security/Fire ...

Ad

Question about SA302 Dual System Smoke Detector

2 Answers

...fire alarm to a combination starter with a hand/off/auto/switch The fire alarm (usually an open contact, held closed during healthy operation) MUST go in series with the supply to the switch. This is ...

Ad

Question about PSU ISTAR|TC-550PA RETAIL (TC550PA) Power Supply

2 Answers

...fire alarm is activated. I have a Ccure Istar panel and I think a apc pwr supply On most fire alarm panels there are normally open and normally closed relays that will change state in the event of a ...

Question about PSU ISTAR|TC-550PA RETAIL (TC550PA) Power Supply

1 Answer

...Fire Alarm Panel and a "Trouble" came into the system as follows: JUNIPER:LOW TRUEALARM VALUE TROUBLE POINT. what does juniper: true alarm true value mean? Call your fire panel representative. I have ...

Question about 4 Zone Conventional Fire Alarm Control Panel

2 Answers

fire alarm panel showing problem on 2 zones Your smoke detectors, heat sensors or fire pull stations (depends on what is installed in your system) are located on your 4 zones. The wiring that connects

Question about 4 Zone Conventional Fire Alarm Control Panel

1 Answer

...fire alarm control panel Late answer I know. But no, the Simplex 2001 is not an addressable fire alarm panel. It is a zoned panel. This panel has not been made for several years and new parts cannot ...

...Fire Alarm Control Panel? I need to ask about a NFS-320/E/C (Fire Alarm Control Panel) and its compatibility with the sensor TC807A 1036 (Smoke detector). There are a new panel like this (replacement ...

Fire Panel and he wantes to tie three tamper switches for PIV and OS&Y to zone 2 of this panel. Is this legal? negative all os&y should be on their own zone. they are programmed differently. A

Question about Ademco Vista-100 Fire And Burglary Alarm

2 Answers

...fire alarm system cercit short panel -ziton fire alarm system I need more information to answer this question, sounds like you might have a ground fault. These are headaches to troubleshoot and it ...

Question about Ademco Vista-100 Fire And Burglary Alarm

1 Answer

...Fire alarm panel, Fire alarm PA system, annunciator panel,hose rill, Hydrant, Fire sprinkler system, Fire pump panel,change-over, MCB, Hose pipe, Hose box, branch pipe, coupling, shutoff nozzle, two ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Home Experts

Donni Steen

Level 3 Expert

687 Answers

john h

Level 3 Expert

20324 Answers

Brad Brown

Level 3 Expert

18060 Answers

Are you a Home Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...