Question about D-E36 Infra-Red Wall Mounted Panel Heater
heater pilot wont stay lit pilot wont stay lit flame wont come on There is a therma-couple that the flame burns against. When it is working correctly it allows gas to travel to the flame. When it goes
...heater to the first position shoots past the brick. we vacumed the bricks out but it is still doing it. do we need to change the brick ? and if so how do we change it? the flame is blue and otherwise ...
...gas wall heater. It has been quite a bit of time now and the pilot just wont stay lit, what other than air in the line could be causing this?? A short pilot flame not playing on the thermocouple or a ...
...gas wall heater, 65"high and 16" wide, it runs for about 10 minutes and shuts off.?? can you help, Thank You>.. I have a 30,000 btu Glo warm wall pack (13 years old ) the pilot lite will not stay lit ...
Question about D-E37 Wall Mounted Panel Heater
...dyna glo) 3 years old, pilot light will not light, get good spark but will not flame. Checked all connections from tank to heater-no problems, propane not coming thru heater to ignitor. What do I do? ...
Question about D-E37 Wall Mounted Panel Heater
...glo-warm propane heater? if there is any adjustment it will be on the gas valve itself under the front of the unit....should have a little door that pulls down....you should see a knob that says ...
Question about D-E36 Infra-Red Wall Mounted Panel Heater
dyna-glo wall gas heater. Set screw for what? To raise the flame? Not one. What you gotta do is clean out the pilot. Least bit of dust makes the safety think oxygen is low and shuts down the heater. I
Question about D-E36 Infra-Red Wall Mounted Panel Heater
...Dyna glo gas wall heater -model RMI-70LP) Both repairable and dangerous. The burner need blown out with a air compressor. This should take care of it. The unit not glowing red will create CO. Which ...
Question about D-E36 Infra-Red Wall Mounted Panel Heater
...dyna glo 30,000btu lp ventless wall heater. I know it needs the ingniter replaced. I have tried to light it by hand and can not. It seams like their is know gas getting thru,is this possible yes you ...
Question about D-E36 Infra-Red Wall Mounted Panel Heater
...dyna-glo 20,000 btu ventless wall heater and the flames are burning way too high so much so it's blackened the white part above the grate what could be wrong possible regulator problem or incorrect ...