Questions & Answers for: carrier 8000 blower

Question about XHB123D X/Y Series Heat/Cool Air Conditioner

1 Answer

carrier 8000 this is a 2 stage furnace. furnace lights but the blower fan comes on before it is hot and continues to run long after the burner goes off. send model no. n manual

Ad

Question about XHB123D X/Y Series Heat/Cool Air Conditioner

1 Answer

...Carrier weathermaker 8000 still no heat what to do have tried turning on heat but nothing Where is the reset switch? go to the furnace, there should be a service switch on the outside of the unit. ...

Ad

Question about XHB123D X/Y Series Heat/Cool Air Conditioner

1 Answer

Carrier Weathermaker 8000 works fine but when shutting down the blower makes a slight sound. Sounds like tapping the bottom of an empty plastic liter pop bottle. Can the blower be lubricated or oiled?

Question about XHB123D X/Y Series Heat/Cool Air Conditioner

2 Answers

carrier weathermaker 8000 won't turn on blinks red light....does anyone have troubleshooting manuals check the filter. If its dirt, clean it, put it back and switch your unit on. weather maker model ...

Question about XHB123D X/Y Series Heat/Cool Air Conditioner

1 Answer

Carrier Weathermaker 8000, inducer fans runs, system lights, exhaust out heats up to above 250 degrees temp and systems shutsdown on safety on exhaust flue. should exhaust temp be so high on induced ...

Question about XHB123D X/Y Series Heat/Cool Air Conditioner

1 Answer

...Carrier Weathermaker 8000 VS furnace that intermittently has frozen up (the inducer blower stops spinning). Do I need to replace the blower or is there something else that can be done? What is the ...

Question about XHB123D X/Y Series Heat/Cool Air Conditioner

1 Answer

Carrier Weathermaker 8000 led stays on constant, blower works and i have power to the controller. no power at the ignitor/gas valve. Check your thermostat level +29 and mode in Heat. If still problem,

Question about XHB123D X/Y Series Heat/Cool Air Conditioner

1 Answer

carrier 8000 weathermaker 92000 btu Furnace overheating, overlimit switch opening, have replaced blower motor and capacitor, control board, and filters. Have cleaned all air supply boxes and ducting. ...

Question about Weathermaker 8000 Gas Furnace 125k Btu

0 Answer

...8000 58TUA doesn't work From time to time, it stops heating. All you need to do is to turn off the switch by the side of furnace and then turn it right back. This always solve the problem right way. ...

Question about Weathermaker 8000 Gas Furnace 125k Btu

1 Answer

...carrier weathermaker 8000 it turns on and one motor runs quiet ook and then the blower starts very loud possible motor loose or squirrel cage out of balance If the blower turns noisy check for any ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions