...heat pump I have a problem with my carrier heat pump. The unit will not change from ac to heat. Not sure what to do. Any suggestions will be appreciated. Check the relays on the main board of your ...
...even if outside temperture below 25 Degrees. Auxiliary heat will be on without being manually activated and compressor will still be running. You are describing normal operation for a heat pump
Question about 52CQ-312-4 Comfort Series Heat Pump Air Conditioner
...motor on carrier heat pump. rewired with new capacitor and still not running. compressor is running until it reaches it's high pressure cut off point. curious of the circuit board. check fan ...
Question about 52CQ-312-4 Comfort Series Heat Pump Air Conditioner
...Heat Pump How can I determine the Age of Carrier Heat Pump SN 300E03782 First four numbers. The first two are the week it was made and the second two are the year. Rus Carrier dealer Your missing a ...
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
...air, but heat pump does not come on. can go to e-heating and furnace works fine. no fuses on heat pump, no reset button and circuit breaker is fine. believe this is electrical, not mechanical. thanks ...
Question about 52CQ-207---3 Comfort Series Heat Pump. 7000 BTUH, 2.3KW, 230V PTAC Air Conditioner
Carrier 52CQ-207 not heating heat pumps are a very complex with many varables it would be best to let a tech come out a look at this for u as there are not alot of serviceable parts thanks
...heat pump or a/c Hi, to tell if your unit is a heat-pump or not, if the indoor unit is not gas fired, it is a split system heat pump. If it uses gas or propane gas, its a split system gas/elect unit. ...
Question about 52CQ-312-4 Comfort Series Heat Pump Air Conditioner
where is the outside air temperature sensor locatedon my carrier comfort series heat pump? It's with discharge pipe line(near to compressor)
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
pump is switching from cool mode and cool air to heat mode and heat by itself after running cool for a few minutes Check your thermostat setting. It must be minimum 4 degrees difference from room temp
Question about XHB123D X/Y Series Heat/Cool Air Conditioner
...air.com/carrier-heat-pump-troubleshooting/ And where did you find this technician?? Need I suggest finding a different one!? Is the heat pump actually running when your tstat is calling for cooling?? ...