Questions & Answers for: Sta Rite ag 6500

Question about Sta-Rite Max-E-Therm High Effiency - Propane Heater - 333,000 BTU

1 Answer

AGS code My pool heater ignites for 1 second and quits or doesn't ignite at all. I am reading an AGS code so I replaced the gas shutoff switch, and the high limit switch with no resolve. I checked the

Ad

Question about Sta-Rite Max-E-Therm High Effiency - Propane Heater - 333,000 BTU

1 Answer

sta-rite gas heater won't ignite sta - rite gas heater comes on, but won't fire. After about 30 seconds the service light comes on and there is a smell of gas. I am not sure if either of these issues ...

Ad

Question about Sr400na Max E Therm Pool & Spa Heater Dual Electronic Ignition Lo Nox 400,000 Btu Natural Gas

2 Answers

Gas pool heater SR400NA Does not turn on. has a digital reading of 123, 124 where the temp reading is located. I had the same problem. My heater would read between 123 and 126. The heater sat all ...

Question about STA-RITE IGNITION CONTROL MODULE - 42001-0052S

1 Answer

pool heater my sta rite pool heater ignition control goes into lockout mode. can you give me some causes for this If the heater fails to ignite after three attempts, the heater will automatically go ...

Question about Sta-Rite Max-E-Therm High Effiency - Propane Heater - 333,000 BTU

1 Answer

Sta-rite propane heater turns on, blower on but it doesn't fire Turns off after 3 minutes and service light comes on. There can be a couple of reasons for this issue to occur. The first thing to check

Question about STA-RITE IGNITION CONTROL MODULE - 42001-0052S

0 Answer

sta rite pool heater service red light is on. Spa is not heating chec gas and is open...water is runing through the system. We followed the troubleshooting guide but we got stuck on finding a board. ...

Question about 18" AG Sand Filter System 1 HP Pump

1 Answer

motor hums, but wont run, it's seized up. What do I do? The first thing to do is to disconnect power to make sure it cannot come on while you are trying to fix it. Determine for sure weather the ...

Question about 18" AG Sand Filter System 1 HP Pump

0 Answer

Sta rite SR200LP Heater will not fire. The failure sequence is: pool on, blower on, water temperature 66 F, service heater led on, then off, heating led blinking and service heater led off, gas valve ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Sta Rite Pool and Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Are you a Sta Rite Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...