Posted on Aug 03, 2011

The compressor was hot and now the compressor pops

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

My coleman powermate inflationmate electric air compressor won't start

check it over and look for the motor and make sure the fuse has not popped out. it will do that for many reasons but mostly if not enough power is available when running or ran too long and got hot.
0helpful
1answer

What could cause loud popping sounds?

The sounds you are hearing is the defrosted water, from auto defrosting, running onto the hot compressor. This evaporates the defrosted water. This is quite normal.
0helpful
1answer

Won't cool down, pop sound on Compressor, is very hot not runing

Rick that don't sound good. If you know how to test the compressor and have a OHM meter we need test. See if fan is running under refrigerator and Click here=> HOW TO CHECK FOR A BURNED OUT COMPRESSOR do that first and then we move to what else may be the problem watch the movies on that page. That pop sound like shortig of start relay or something related to compressor. Please rate my solution after I have helped you resolve the problem and communicate with me. I am offering my help to you free. If need you may contact me here on Fixya or my Forum=> Appliance 911 My contact information is located above the Fixya Ad on my blog here=> Sea Breeze Appliance Parts and Technical Services, www.pcappliancerepair.com
Thanks, Sea Breeze
0helpful
1answer

Brick Air blowing hot air

if you hear the compressor turning on,no heat, the coolant has leaked out. if the compressor doesnt turn on, its a control issue.
0helpful
2answers

A/c went pop and hot air started pouring out.

Possibly compressor belt broken. Maybe sudden loss of coolant gas. Fix bad part and recharge.
0helpful
1answer

The compressor gets hot and trips the breaker

More than likely what happen was the internal overload in the compressor was tripped and didnt reset for 5 hrs and when it did it popped the breaker. The compressor was probably already shot. Sorry
2helpful
1answer

Cooler no longer cooling

That POP noise sounds as though it is the overload on the compressor. Although personally I would describe it as a CLICK. If it is then you are either looking at a start device failure (relay or capacitor) or more likely a compressor failure. If you check underneath at the compressor side (black circular unit) and put your hand on the compressor if it is hot you are probably looking at a new compressor. Unless you have electrics for the compressor the only real solution is to have this confirmed by a fridge engineer. If it is the relay I would expect a bill of around £80 if it is the compressor thn it can be between £200-£400 depending on the size of the compressor. Hope this is of some help.
Not finding what you are looking for?

42 views

Ask a Question

Usually answered in minutes!

Top Haier Refrigerators Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66944 Answers

vince

Level 3 Expert

2530 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Haier Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...