1) T101P201 timer does not have a separate manual yet
http://www.poolandspacontrols.com/products/mechanical%20time%20switches/pool%20and%20spa%20time%20switches.aspx
2) However typical T101P201 timer is ordinary T101 timing mechanism inside Nema 3R beige-colored outdoor plastic enclosure, with additional fireman's switch.
Wiring for T101 shows on following link, and shows on door of timer enclosure:
Check that your timer terminals match illustrations because many timers can fit inside Intermatic enclosures.
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101
3) Fireman switch wiring:
T101P201 has a fireman's switch that wires directly to the pool heater thermostat.
http://waterheatertimer.org/pdf/Intermatic-Firemans-switch-156T4042A.pdf
If you are not using the timer for pool heater, or if heater does not have connection for fireman's switch, then do not connect fireman switch wires, and just tape them out of the way.