The solution is not quite clear. Please simplify it. Im receiving an f6 error,which would be indoor fan failure but i would like to clarify before i touch anythngThe solution is not quite clear. Please simplify it. Im receiving an f6 error,which would be indoor fan failure but i would like to clarify before i touch anythng
You can't post conmments that contain an email address.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
•Improper cartridge (Destination error, life cycle error) •Identific t ion error •Model error •Type error •Destination error •Data abnormality •Misc error Detail •The destination of the machine differs from that of the CRUM. •The trade mark code of the CRUM differs. •The company code of the CRUM differs. •The boot program model code does not coincide with the CRUM model code. •When the CRUM type is other than genuine/ conversion/production rotation. •The machine destination differs from the CRUM destination.
CC
Original not detected
E1
00
Lost communication with the Sorter
10
Lost communication with the Sorter
11
ASIC error
12
Image Processing Unit error
13
ROM error
14
NVRAM error
15
Page memory fault
16
SIMM not present or installed incorectly
17
Page rotation error in RAM
80
Electronic sort board error
81
82
84
88
E7
03
Lens position error
04
White level calibration error
05
Black level calibration error
12
CCD calibration error
F1
06
Shift sort motor overloaded
F5
02
Exposure lamp blown
F6
00
Fax board problems
10
80
81
82
84
88
F9
00
Printer board problems
10
80
81
82
84
88
H2
00
Fusing unit temperature error
H3
00
Overheated fusing unit
H4
00
The fusing unit doesn't heat up
L1
00
Scanner position error
L3
00
Scanner position error
L4
01
Main motor drive overloaded
10
Separation motor overloaded
L6
10
Polygon mirror motor not up to speed
L8
01
Zero cross signal error
U2
04
EPROM error
11
Main counter error
12
EPROM error
U3
29
Mirror position error
U9
00
Op panel problem
81
82
84
88
U95
Firmware error
To find out the sub code for the U2 error hold down the Start key. Below is a list of the errors:
U2-04 EEPROM serial communication error
U2-11 Counter check sum error
U2-12 Adjustment value check sum error (EEPROM)
U2-40 CRUM communication error
To clear the U2-40 error try pulling out the toner cartridge and firmly reinstalling it. If that doesn't work you must install a new toner cartridge. There is a CRUM chip on the cartridge that keeps up with how many impressions have been made with that cardridge. You cannot "refill" these cartridges without replacing the CRUM. This problem occurs frequently with remanufactured cartridges.
To clear other U2 errors you must enter simulation mode. Perform the following procedure to enter the simulation mode. Clear key - Interrupt key - "0" key - Interrupt key - 16 - Start key - Start key. The unit should reset.
when you turn on the machine it rotates and takes severaal readings from different sources. one of them is for the drum, adjusting the seperation to the age of hte drum. So as the drum ages with the amount of copies it automatically adjust it self. Have the tech replace that sensor (if they haven't done so) or maybe it just has toner on it giving false readings.
An F2 code depending on the secondary code is related to the toner or drum.
F2 00 Toner control sensor open 22 LCC 24v power abnormality 02 Toner motor connector unconnected 50 Non supported option connection (Desk Unit) 31 Process control trouble (Drum surface reflection) 51 Non supported option connection (LCC Unit) 32 Process control trouble (Drum Mark) U7 00 RIC communication trouble 37 Drum marking sensor gain adjustment error U9 00 Operation control communication trouble (ICU) 39 Process thermistor breakdown
×