Question about Mitsubishi WS-65809 65" Rear Projection Television

1 Answer

Mitsubishi WS-65809 65 in. (Won't stay on)

I go to turn it on and the red light indicator comes on for 1 second and then it clicks off. The TV screen does nothing. I checked the clear bulb (fuse) by were the power supply comes in and it's OK.
this is about 6 years old now and has been a great TV till this.

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 927 Answers

Good Day, 4mlspro;
You can try this or call an Authorized Service Center and get an estimate on the repair, $450.00 to $650.00;
This model is equipped with a self-diagnosis feature to help with diagnosis of shutdown problems. To activate this turn the unit on let it shutdown then press the input and menu buttons on the front panel simultaneously and hold them in for 5 seconds after 5 seconds the power LED on the front panel will blink a two digit sequence. This will be one set of blinks a short pause then another set of blinks, this will repeat 5 times. 1 - 2 = no error detected 2 - 1 = X-ray protect (high voltage or beam current) 2 - 2 = Short protect (short protect monitors low voltage supplies) 2 - 3 = Deflection protect (this could be loss of vertical or horizontal deflection) 2 - 4 = Vertical protect (usually loss of vertical from the source) 1. SHUTDOWN AT POWER WITH SELF DIAGNOSIS ERROR 2 2. CHECK FOR LEAKY C9A60 470 PF 1000 V PART # 154P400030, PARALLEL TO D9A57 ON THE POWER PCB (NOT SHOWN IN THE SCHEMATIC). 2. SHUTDOWN AT POWER WITH SELF DIAGNOSIS ERROR 2 2. CHECK FOR OPEN FUSES F9A04 AND F9A05 PART # 283P043090 ON THE +24 AND -24 VOLT LINES. IF THE FUSES ARE OPEN THE CONVERGENCE OUTPUT CIRCUIT WOULD BE SUSPECT. 3. SELF-DIAGNOSIS INDICATES SHORT PROTECT. CHECK FOR A SHORTED IC4B01 PART # 270P261020 (VERTICAL OUTPUT) LOADING 24-VOLT SUPPLY LINE. LOCATED ON THE MAIN PCB. Good Luck, big IRISH.

Posted on Aug 31, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What's your problem?The tv comes on for 1 second and turns off and the red lamp light is on


Replace the lamp. The red lamp light is indicating an issue with the lamp. You can get the replacement lamp with installation instructions from www.tvrepairworld.com

Oct 19, 2012 | Mitsubishi Projection Televisions

1 Answer

Mitsubishi WS-65511. Won't stay on.


Bad filters in the main microprocessor. good luck.

Aug 30, 2009 | Mitsubishi WS-65511 65" Rear Projection...

2 Answers

My model is a WS-55511. I turn on the TV, the


Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} MOST OF THESE SETS HAVE A SELF DIAGNOSTIC:


UNPLUG TV AND THEN PLUG BACK IN---TURN ON---GREEN POWER LIGHT COMES ON FOR A MOMENT AND GOES OFF.

PRESS AND HOLD “device” and “menu” buttons on front of tv for at least 5 seconds and then release both together.


Watch for power light to blink in a sequence:

1 blink-then 2 blinks-------no error

2 blink-then 1 blink-------X-ray protection

2 blink-then 2 blink-------SHORT PROTECTION*******

2 blink-then 3 blink---------deflection circuit problem

2 blink-then 4 blink---------vertical circuit problem


******2, then 2 is most common---usually means one of the fuses that protect the Convergence IC or IC’s is blown---set will detect no voltage to convergence IC and shut down.


SET WILL REPEAT BLINK ERROR CODE UP TO 5 TIMES AND THEN TO GET IT TO REPEAT MORE YOU HAVE TO UNPLUG SET AND TRY TO TURN ON AGAIN.


IF IT IS 2 AND THEN 2---USUALLY
CONVERGENCE CIRCUIT PROBLEM

Aug 08, 2009 | Mitsubishi WS-55511 55" Rear Projection...

1 Answer

Stays on for 2 seconds and switches off


A 2-2 code on that unit means over current shutdown. 95% of the time that code indicates defective convergence output IC's.

Jun 09, 2009 | Mitsubishi WS-65869 65" Rear Projection...

1 Answer

My tv ws-55819 tv won't turn on it cliks on but it won' syat on


ok when the power is plugged in hold down the menu + device buttens for five sec what is the error code there should be two sets of numbers....
like 1 pause 2 let me know and i'll see what i can do!

Feb 01, 2009 | Mitsubishi WS-55819 55" Rear Projection...

2 Answers

Tv will not power up, shuts off after 10 second


http://serviceman.site88.net/index_files/MitsubishiTV.htm

Oct 01, 2008 | Mitsubishi WS-65857 65" Rear Projection...

1 Answer

Mitsubishi HDTV 1080 WS-55859. Error Code 12


Did you push in the device and the menu buttons at the same time and get the error code...  I have the same problem and I get a 1,2 code....   I am looking for what the codes stand for...
Have you got any help on this....
Scott
mu email is smartin38@verizon.net

Sep 11, 2008 | Mitsubishi WS-55859 55" Rear Projection...

2 Answers

Lightning strike


press menu and input both in together on the front of the TV and hold them both in together for 8 seconds then let me know if the LED blinks a two digit code.

Jun 10, 2008 | Mitsubishi WS-55315 55" Rear Projection...

Not finding what you are looking for?
Mitsubishi WS-65809 65" Rear Projection Television Logo

212 people viewed this question

Ask a Question

Usually answered in minutes!

Top Mitsubishi Projection Televisions Experts

matt martin
matt martin

Level 3 Expert

1191 Answers

Jaime Hernandez

Level 3 Expert

2267 Answers

The Knight
The Knight

Level 3 Expert

68352 Answers

Are you a Mitsubishi Projection Television Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...