Question about DeLonghi Pinguino PACL90 Portable Air Conditioner

1 Answer

DeLonghi Pinguino PACL90 MODEL

WE BOUGHT THIS PORTABLE UNIT 3 YEARS AGO FROM SAMS CLUB. NO PROBLEMS TIL THIS WEEK. IT WON'T COOL THE ROOM. I'VE EMPTIED THE INTERNAL CIRCUIT OF WATER, WASHED THE DUST FILTER, VACUUMED THE 3m ELECTROSTATIC FILTER. THE VENTS ARE CLEAR AND AIR BLOWS OUT. IT STILL DOESN'T COOL. I DON'T WANT TO ORDER A NEW 3M FILTER SINCE I DON'T KNOW IF THIS IS THE PROBLEM. CAN I TURN THE UNIT ON FOR A WHILE WITHOUT ANY FILTERS IN PLACE, TO SEE IF IT IS THE FILTER BEFORE I ORDER A NEW ONE? I THINK IT'S A DIFFERENT PROBLEM, POSSIBLY THE FREON. PLEASE ADVISE. THANKS JUDY

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 1,420 Answers

For a short time you can run without filters. I suspect it is low on charge or the metering devise is not working. Check this link out for an owners manual. It may help you.
http://www.manualnguide.com/download/manual-guide/delonghi-pinguino-pac210-portable-air-conditioner-owners-manual.html

Posted on Aug 19, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Cooling issues (low refridgerant?)


Make sure both the evaporator and condensor coils are clean. After the unit has been off for a couple of hours, start it back up and measure the temperature difference between the air entering into the unit (room air temperature) and the air blowing out of the unit and into your room. You should have approx 20 deg......take this measurement after approx 5 minutes of run time. If the temperature difference less than 15, you may very well have a refrigeration problem. If it is approx 20 degrees, then it could be a dirty coil or an electrical problem.......inspect all of your electrical wires and controls for any signs of overheating.....tighten all connections.

I hope you find this to be very helpful in your diagnosis. :-)

Mar 23, 2010 | DeLonghi Pinguino PACL90 Portable Air...

2 Answers

DeLonghi Pinguino PAC CT90 It is less than a year has quit coolin


Read instructions and see if it says anything about cleaning or filters. A.C units **** air in and there is a filter that probably needs cleaned.Also,while cooling, the vent to the outside should put out warm air. Also, if it is less than a year old, contact the manufacturer and they should help you out. Good luck.

Feb 13, 2010 | DeLonghi Pinguino PACL90 Portable Air...

2 Answers

Identicial problem, and yes in the same room for 3 years


It's a sealed system wich normally doesn't need to be recharged. (compare with a fridge)

Frans Verhees
service engineer.

Sep 17, 2009 | DeLonghi Pinguino PACL90 Portable Air...

1 Answer

DeLonghi portable airconditioner leaking water


nbenz ,

Welcome to fixya.
I'm Huuum and happy to assist you,

Portable units are supposed to spray the water on to the hot compressor an evaporate the water!
If it is only 3 weeks old ,you have a 1 year warranty. call service and let them fix it for !




Please remember to leave a rating before you go!
Thank you

Aug 26, 2008 | DeLonghi Pinguino PACL90 Portable Air...

1 Answer

Blows room temperature air


Hello
Welcome to fixya.
I'm Huuum and happy to assist you

The air conditioning
unit works, but does
not cool the room

• window open
• there are heat sources in the room (burner,
lamp, etc)
• the exhaust hose is detached
• air filters clogged
• Inadequate size of the room (too large)
• close the window
• eliminate the heat source
• connect the exhaust hose
• clean or replace the filters
If all this dose not remedy the problem then you need to see service!

Please remember to leave a rating before you go!
Thank you

Jul 13, 2008 | DeLonghi Pinguino PACL90 Portable Air...

1 Answer

Probe Failure


i service the delonghi brand in tampa fl we have seen alot of probe failures. some last years some go out in 4-5 hrs of usage

Jun 19, 2008 | DeLonghi Pinguino PACL90 Portable Air...

1 Answer

Delonghi Pinguino PacL90 replacement hoses


Delonghi Replacement Parts:  800-865-6330
They only open Monday through Friday from 8:30 - 5:00.  Not much help when the unit goes out on a weekend.
Be very familiar with your product before calling.  I dealt with a few incompetent people before I got to someone helpful.

Jun 08, 2008 | DeLonghi Pinguino PACL90 Portable Air...

1 Answer

Delonghi AC problem


suspect a faulty running capacitor.

Apr 24, 2008 | DeLonghi Pinguino PACL90 Portable Air...

Not finding what you are looking for?
Air Conditioners Logo

Related Topics:

626 people viewed this question

Ask a Question

Usually answered in minutes!

Top DeLonghi Air Conditioners Experts

Michael Youngman
Michael Youngman

Level 2 Expert

156 Answers

Sudeep Chatterjee
Sudeep Chatterjee

Level 3 Expert

3267 Answers

Mike

Level 3 Expert

4331 Answers

Are you a DeLonghi Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...