Question about Jandy Laars LX Pool Heater / 400,000 BTU / Natural Gas

1 Answer

Pool heater says low pressure - Jandy Laars LX Pool Heater / 400,000 BTU / Natural Gas

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Jandy Master
  • 6,394 Answers

If filters are clean check pressure switch if 24 volts on both sides ok if not check copper tube for blockage you can jump just to check

Posted on Mar 05, 2016

Ad

4 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 1 Answer

SOURCE: low pressure reading on Pool Heater

I had this problem with ours last year. I replaced the water pressure switch and it began working fine. We later had a symptom that the blower would start but it would not ignite. The ignitor rod was corroded so I took it out and sanded it with some sandpaper---worked fine...until I dropped it trying to reinstall and it broke. Bought a new one and it works fine now.

Today's problem is related to the blower now.... it is always something, isn't it?!?

Posted on May 30, 2009

  • 990 Answers

SOURCE: my laars lx pool heater is blinking LOW PRESSURE.

The heater needs good water flow or it will overheat. You probally have a full basket in your pump or your filter is dirty.

Posted on Jan 21, 2010

  • 1 Answer

SOURCE: Message 'LOW PRESSURE' on my Jandy LX pool heater.

This isn't a solution, but a question after having the same problem and doing some troubleshooting. I removed the water pressure switch in the heater and turned on the pump and water flows nicely out of the copper tube for the water pressure switch. Next I replaced the pressure switch and removed the two wires and shorted them together, being as a switch is either on or off, shorted or open. I confirmed that the short is seen at the connector going into the control panel. I still have the low pressure light blinking. What now?

Posted on Jul 24, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

What does lo mean on my h250 hayward pool heater


LO standss for limit open. the most common cause is lack of adequate water flow through heater. other causes are high temp limits.

Jun 10, 2014 | Hayward H Series Pool & Spa Heater 400k...

1 Answer

Air energy electric pool heater shows low pressure, low temperature and will not turn on


low pressure will either be gas or water. technician with a manometer can check gas inlet and manifold pressure. ensure adequate water flow from pump. pressure switches generally close at 2psi. you can jump the pressure switch if you think its faulty, or use ohm meter and check continuity of pressure switch