Question about Thermador Microwave Ovens

Open Question

Mine is a Thermador Option 3 Micro Convection oven. The power went completely off after it ran for about 20 seconds of a 2 minute time, re started for about 20 seconds and then went completely dead. No clock, no key pad........ Oven seems to be working

Posted by on

Ad

5 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 1 Answer

SOURCE: Panasonic NN 9850 wall micro/convection oven

PLEASE CHANGE MEMBRANE SWITCH

Posted on Oct 05, 2007

Ad
MicrowaveSvc
  • 9047 Answers

SOURCE: Microwave stops after about 2 seconds, also have to reset the clock each time

TO mdambros

You have a bad magnetron. We see this over and over.

If it's within the magnetron portion of the warranty (usually 5-9 years) but out of the original full warranty (usually 1 year), then your manufacturer will cover the part cost, but not the cost to visit you or the labor charge to do the work.

You'll save a lot by taking it in yourself.

If you or someone you know decide to look into it, we have critical information on safety, disassembly and door switches at our site, and our link is at our listing here on FixYa: http://tinyurl.com/yzjozk

There should also be a "mini-manual" hidden inside the unit behind the control panel or hidden on the left side behind the grille, which is very helpful when troubleshooting.

You can find helpful exploded view diagrams and order parts by entering your full model number here: http://tinyurl.com/gv383

We're happy to help and we appreciate your thoughtful rating of our answer.

TO guest (Panasonic oven)

The door switch you suspected is bad, and it must be replaced. They normally cannot be cleaned or burnished and be reliable.
See http://www.microwavedisplay.com/doorsw.txt

Please feel free to contact me directly if you need more help.

We're happy to help and we appreciate your thoughtful rating of our answer.

William E. Miller, AS-EET
prototech@usa.net
http://www.microwavedisplay.com

Posted on Jul 01, 2008

MicrowaveSvc
  • 9047 Answers

SOURCE: thermador microwave from oven/micro/warming drawer

The first thing I would suggest is a hard reset. Unplug the unit for a minute or so. Then plug it back in, set the clock and try again.

Let us know if the hard reset does not fix it.

Posted on Aug 21, 2008

MicrowaveSvc
  • 9047 Answers

SOURCE: jvm1190 over range micro/convection oven

If the hood vent exhaust fan came on by itself, that was due to excessive heat on stove top, a failure of the hood TCO (thermal cutout / thermostat) or a problem on the control circuit board (smart board) which we regularly repair for customers nationwide by mail for $39.95 postpaid in about a week with a one-year guarantee.

There should be a "mini-manual" (tech sheet) hidden inside the unit behind the control panel or hidden on the left side behind the grille, which is very helpful when troubleshooting, testing, and locating components.

d:%5cele%5crepair%5cmicrowave%5cge_hotpoint%5cmini_manual_behind_grille_small.jpgdee77f7.jpg

At our Web site, we have a video available showing how to remove a typical over the range control panel assembly in under 5 minutes.

In this model, there are three TCOs which could be open, rendering the oven dead: The bottom TCO (not to be confused with the hood TCO, which should be normally open) the heater TCO and the magnetron TCO.

Also, the fuse should be checked in the unit.

Accessing some components for testing and possible replacement will require you to remove the oven from the wall.

If so, the installation instructions are very handy, and it's best to have two people since the microwave can be heavy and awkward.

You can download GE owner's manuals and installation instructions here.

You can find helpful exploded view diagrams and order parts by entering your full model number from the tag on the oven here.

After you look into this, if you still need help, please write back with more details.

Feel free to contact me directly (and please remind me of your full model number) for more information & help or see our Web site.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. "Ed" Miller, AS-EET
prototech@usa.net
http://www.microwavedisplay.com

Posted on Feb 15, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Would like specifications to JVM1850SM2SS


  • 1.8 CF Oven Cavity
  • Electronic Touch Controls
  • 950 Watts
  • Display On/Off Yes (option pad)
  • Add 30 Seconds Instant-On
  • Cooking System CircuWave┬«
  • Defrost - Auto / Time / 1 lb. Quick Defrost
  • Delay Start
  • Express Cook Instant-on 1-6 minutes
  • Instant On Controls
  • Micro / Time Cook I & II
  • 10 Power Levels
  • Wire Oven Rack
  • Cooktop Lighting - Bright/Night/Off
  • Demo Mode
  • Interior Oven Light - Halogen
  • Night Light (option pad)
  • Child Lockout
  • Easy Mount Installation
  • Exhaust Fan 3 Speed Plus Boost (315 CFM)
  • Cooking Complete Reminder
  • Timer (On/Off)
  • Reminder (24 hr)
  • Sound Volume Control - 4 levels
  • Sensor Controls
  • Beverage Instant-On
  • Popcorn Instant-on
  • Potatoes Instant-on
  • Reheat Instant-On
  • Sensor Controls
  • Vegetables Instant-on, 3 pads (canned, frzn, fresh)
  • SmartControl System
  • Clock Plus AM/PM pad
  • Concurrent Programming
  • Custom Pad
  • Electronic Scrolling Digital Display - 2 line
  • Help Pad
  • Variable Scroll Speed - 5 Speeds (Options Pad)
  • 14.25 " Turntable - Glass Recessed
  • Turntable On / Off
  • 2 Wire Oven Racks; 2 Positions
  • Recirculating Charcoal Filter Kit JX81B

Dec 15, 2014 | GE Microwave Ovens

1 Answer

Thermoststat defective need new one


they only make 2 types...normally open or closed 155 degrees + or -

use a VOM reed the old one if it shows open you need a normally closed thermostat..$5 or less

Apr 11, 2014 | Thermador 30 inch Masterpiece Series...

1 Answer

Thermador warming drawer takes 45 minutes to reach 190 degrees on high setting! That can't be right! Tech support said it should be 220 degrees on high and should take 20 minutes to fully heat.


I recommend that you go with your microwaves and claim to fix it. This can be a problem with magnetron, or power diode, capacitor faulty, or thermostat.

God bless you

Oct 27, 2013 | Thermador 30 inch Convection Warming...

1 Answer

Microwave shuts down after 2 seconds


unplug the appliance from the main socket and plug it after sometime

Jun 07, 2013 | Thermador MCES MCEB Convection Microwave...

1 Answer

If you try to heat something for a minute , the microwave will turn on for about 15 seconds then shut off . It doesn't even seem to warm the food.


It may need a reset. You can do that by unplugging the power for a minute or two, then plugging it back in and setting the clock.

If it still fails, you may have a failing cooling fan or a problem on the control circuit board.

Apr 14, 2013 | Thermador MCES Stainless Steel 1000 Watts...

1 Answer

I had power outage and now all the number on the timer and thermometar are a mess


The microprocessor has been scrambled due to power surge when it came back on. There is only possible thing you can try, unplug the oven for 30 minutes and plug it back in, this might reset the ic, if not you will need appliance repairman to assess the situation.

Feb 05, 2011 | Thermador MCES MCEB Convection Microwave...

1 Answer

LG LMVM2055ST Microwave. went completely dead, completely


I replaced outer door with key panel on my LG MICRO MODEL LMVM2055ST which solved my problem but when I went to put the handle back on it did not fit. The tophole in new panel for the handle is round and the old one is rectangle. LG says I have right part can not help me.A new handle comes rectangle shape. What now?

Mar 15, 2010 | LG LMVM1935 Convection/Microwave Oven

1 Answer

Thermador microwave from oven/micro/warming drawer not keeping time correctly. clock is shaking and running 3-4 hours behind.


The first thing I would suggest is a hard reset. Unplug the unit for a minute or so. Then plug it back in, set the clock and try again.

Let us know if the hard reset does not fix it.

Aug 21, 2008 | Thermador Microwave Ovens

Not finding what you are looking for?
Microwave Ovens Logo

Related Topics:

174 people viewed this question

Ask a Question

Usually answered in minutes!

Top Thermador Microwave Ovens Experts

William Miller
William Miller

Level 3 Expert

9047 Answers

Jerry Greenberg
Jerry Greenberg

Level 3 Expert

1667 Answers

Cindy Wells

Level 3 Expert

5129 Answers

Are you a Thermador Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...