I have Marey nat.gas.water heater (3 years old) now the flame goes on for a second and goes off ,pezo try to restarted but wont go back on ,any solutions ?? many thanks

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

  • Expert 281 Answers
  • Posted on May 22, 2011
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

Joined: May 05, 2011
Answers
281
Questions
0
Helped
59463
Points
738

Sounds like your thermocouple is shot.It's that

little tube that the pilot light heats up.I am

assuming that you have started this heater

before.The thermocouple has to stay a certain

temperature to keep the gas flowing.You can buy

universal thermocouple kits at your local

hardware store.Make sure gas is turned

off.Loosen the coupling nut on the outside of

the tank then remove the tin and remove the

heating part.The whole thing is a small 1/8

tube.Bend new one like the old one and put it

back in place.If the kit has yellow Teflon tape

wrap the threads on the coupling and

tighten.Turn the gas back on and test for leaks

with soapy water.Thanks for choosing FixYa.com.

I always add this for your information. If this

is not the solution that you are looking for

please re post because when we pick a question

to answer FixYa takes it out of the questions.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

We need to find out what is wrong with our hot water heater. It is a Marey 180. It quits heating water. You can cut it off for several hrs then cut it back on and it will heat again

Hello, busby_betty -

Clarification: You have a Marey ECO180 Electric Tankless Water Heater. If so, I checked the owner's manual, here:
https://marey.com/english/products/electric-water-heater/whole-house/eco180.html
in case your problem was mentioned in the Troubleshooting section. It wasn't.

Therefore, before you call for a repair technician to come and evaluate your water heater, I suggest you telephone the Marey Customer Service number: 855-627-3955 to find if the Customer Service representative has any ideas on what needs fixing. Or, you can send an email: [email protected] .

When you contact Marey Customer Service, ask about the nearest authorized Marey water heater service business, so you may call and make an appointment for a service technician to come to your home and check what is wrong and repair it.

If you were hoping an authorized Marey water heater repair person was sitting on Fixya.com waiting for questions about Marey water heaters, that isn't the case.

Note: It may be a problem with the water heater thermostat or the or the heating sensor. Also, check the information here:
https://www.doityourself.com/forum/water-heaters/548564-help-marey-electric-water-heater.html
(Copy the URL and paste it into the address box of your browser, if it isn't hightlighted as a link.)

The real problem may be with the electrical wiring and circuit to which the water heater is connected.
0helpful
1answer

Ignition problem

Sometime the batteries in the drawer fade (yes even new ones). I am asking, is that after the flow initially stops, the Automatic Start will not fire up when there is a demand for hot water (Is this what you meant when you say "The water is turned off" and "Then on again". Check the batteries for being the right way around (I Have installed them 1/2 forward and 1/2 back ward as a set, the one cancelled the other one out....my Bad....Ooops) The battery should be only needed if the power fails, but not sure about this model. Does the Owners manual say anything about no hot water? IF that was tried, you may need to call the heating / cooling techs that are familiar with this unit.
0helpful
2answers

Rheem RTG-64DVN model, brand new unit installed during the weekend. fired up but shout down automatically within about 5 seconds. showed error code 12.

contact your gas company if the error code is "12," indicating that the gas supply was interrupted.

have a good day !! In LP models, the 12 error code may also appear if the LP gas supply has gotten low. To clear the code, replace or refill the LP gas supply.

go here for a list of codes for rheem tankless water heaters-- www.ehow.com/list_7833182_error-rheem-gas-water-heater.html
1helpful
1answer

I have a richmond 5v40-36f water heater & when i light the pilot it stays on for 20-30 seconds,then when i turn it to ON it lights the burner for 3-5 seconds then goes out,i replaced the thermacouple...

Do you have a natural gas or propane water heater. You could possibly have a dirty valve which stops the flow of the gas. Has there been a change with the environment of the water heater. Check for the draft and back blow of the available air. If the water heater is over 6 years old maybe it is time to replace the unit. Good Luck
0helpful
1answer

Pilot light goes out randomly on 6 year old Bosch Aquastar tankless water heater. When I restart it it may work for a day then goes out again.

The pilot light can be blown out just by the main gas being ignited especially if the pilot flame is a little weak. Some times a bit of grit gets into the pilot nozzle reducing the flow and hence a weak flame. Try cleaning the piolt jet nozzle with a fine piece of wire. You may have to dismantle the jet nozzle to clean it properly.
1helpful
2answers

I have a two year old a.o. smith powervent water heater and it cycles on and off constantly.. If I reset it by powering it off and back on, it sometimes works for a while. it appears to be getting...

The flame sensor is not sensing flame and the unit shuts off on safety. You can try cleaning the sensor, but will likely have to replace it. Also clean the burners. Sometimes there can be rust, dirt, or other dibri that causes an improper flame pattern and prevents the sensor from being fully in the flame.

With some units, the flame sensor is a seperate part, with others it is a part of the ignition assembly. Those can typically run 30 to 80 dollars for the part.
2helpful
1answer

AO Smith water heater about 4 years old pilot went out took out piolt assembly cleaned and was able to relight pilot unit stayed working for about 2 weeks and went out again any ideas?

It sounds like your flame detector (usually a thermocouple) has gotten weak and when you cleaned the pilot the stronger flame was able to generate enough power to keep the gas valve working. If you replace the thermocouple your problem should go away. If a new thermocouple will not keep the gas valve operating...the coil in the gas valve has gone bad and you will need to replace the gas valve assembly. (most valves do not have replaceable coils).
1helpful
1answer

Rheem 50 Gal Hot Water Heater will not stay lit

On the back of the gas valve (where you turn the temp up) there is a stem that actually goes into the tank that senses the temprature of the water it could be dirty or buried in sediment depending on how old the tank is, or just bad. if the tank is over 10 years old i wouldn't bother replacing the gas valve, the tank is probably not far behind. A new valve will run around $100.00 maybe a little less. You wont find it at menards or home depot in stock but they may be able to order it for you. Menards sells rheem products or try you local plumbing supply house. REMEMBER TO RELIEVE THE PRESSURE ON THE TANK BEFORE YOU WORK ON IT. IF YOU CHANGE THE VALVE DRAIN IT FIRST!
Not finding what you are looking for?

254 views

Ask a Question

Usually answered in minutes!

Top RTO Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a RTO Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...