Hello Amvmotors,

I understand that you want to convert your Natural Gas unit to LP (Propane) gas you will need to purchase a conversion kit. Please give me about an hour or so and I will locate it and the instructions to convert.

Thank you for choosing FixYa.com

Justin

Posted on May 17, 2011

  • Justin Burnett
    Justin Burnett May 18, 2011

    Hello Amvmotors,

    I understand that you are needing a repair kit for your Thermador PG484GGBS. I have located the conversion kit and the instructions for you to follow. You will need to DOWNLOAND THE INSTRUCTIONS and print them so that you can follow them as this is a very sensitive thing to do and must be done right. The part number to the kit is SNLPKITF and can only be purchased from Thermador you will have to contact them at 1-800-735-4328 Monday to Friday from 5am to 6pm PST.

    The INSTRUCTIONS -http://www.thermador.com/accessories/snl...

    Thank you for choosing FixYa.com

    Justin

×

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Convert LP Lincoln oven Impinger II series 1700 to natural gas series 1600


Yes. You need a set of natural gas orifices to replace the LP ones on the oven and all the burners too.

Jan 28, 2014 | Ovens

1 Answer

How do I convert from liquid propane to natural gas


You need parts from the manufacturer. The gas orifices are different sizes between natural gas and LP gas. If you try natural gas with an LP gas orifice, you will not get much flame. If you use LP gas with a natural gas orifice, you will burn off your eyebrows and possibly other things.

Dec 19, 2013 | Capital Cooking Titanium X CCE26XRBI (NG)...

1 Answer

What is the product # for the conversion kit from nat gas to lp? who carries this item? Does the conversion kit come with a regulator?


Some Thermador ranges are not field convertable from natural gas to LP. The PRG364EDG falls in this category. If you have one that is not convertiable; you will need a different range.

The PG364GEBS is not a listed unit at Thermador; I've found it for sale at AJ Madison. Since that vendor doesn't list the conversion kit (and they sell ones for other Thermador ranges), I do not believe this is a field convertible unit.

Thermador has manuals and installation guides for many of their appliances here: http://www.thermador.com/trade/specifications-guides . Most Thermador ranges come with the installation guide, as well as the owner's guide, if you still have your documentation. Otherwise, try the Thermador site for the documentation (check if the company uses a different part number internally). If the conversion kit is available, the part number will be provided in the section on the Gas Requirements and Hookup. If it isn't, the installation guide will clearly state that fact.

Other models are convertible. The PRD304GHU uses the conversion unit: PALPKITHC. You will need to confirm your model since the number of orifices will depend on the number of burners and the low simmer feature. (The PRD304GHU is also a 4 burner with 2 of them extra-low simmer burners model.)

For units that are convertible, you can usually order the part through the same stores that sell the appliance. Alternatively, have your gas service installer order the parts. The installation guide for the conversion kit will be included in the kit. For most ranges that are field convertable, the regulator converts from natural gas to LP by rotating a cap in the regulator by 180 degrees. (Take out the part, turn it over so that LP shows and reinstall.)

I hope this helps and I wiish that I had better news for you.

Cindy Wells

Mar 03, 2011 | Thermador PG364GEBS Stainless Steel Gas...

1 Answer

Gas stove need to switch to propane


Hi,

Hotpoint supplies the orifices and instructions with each range for converting. It is just that it is hidden, they attach it to the gas regulator. The regulator is near the bottom back typically. Here is a cut out from your use and care manual.

CONVERTING TO LP GAS (or converting
back to natural gas from LP)
This range leaves the factory set for use with natural
gas. If you want to convert to LP gas, the conversion
must be performed by a qualified LP gas installer.
The conversion instructions and LP orifices can be found
attached to the range next to the pressure regulator.
Keep these instructions and the orifices in case you want
to convert back to natural gas.

May 13, 2010 | Hotpoint RGB745 Gas Kitchen Range

1 Answer

Converting a Propane Thermador 36" range to Natural Gas


I have the same range but need to convert it from natural gas to propane....we should trade...9j antiques

Aug 31, 2009 | Thermador PGR366 Gas Kitchen Range

1 Answer

Natural gas to lp conversion kit for a Thermador GGNCV30 cooktop


Your LP gas provider will get the orifices for you just call them with the model number of your thermador. They have gotten them for me many times.

May 07, 2009 | Thermador SGS36GS Gas Cooktop

1 Answer

Converting a GE Profile Gas Range from LP to natural gas


GE ships gas ranges set for natural gas, with the LP orifices included, usually on a metal tab held with one screw right near the regulator (where the gas connects to the range). If the range was converted to LP, the person who did the conversion was suppose to put the natural gas orifices back in that holder. If they are missing, comment back on the exact model number and I can look up the part number(s) for you.

Jan 06, 2009 | GE Profile Spectra JGBP90 Gas Kitchen...

1 Answer

Need to convert a Thermador cooktop from Natural to LP


http://www.repairclinic.com/SmartSearch/SSPartDetail.aspx?PartID=1048620&PPStack=1
try this link.
do not drill out the jets they will not work properly.
I would check all your documentation you may have the convention kit with your owners manual or it may be attached to the oven.

Nov 15, 2008 | Jenn-Air JED8430 Electric Cooktop

2 Answers

Conversion


call the dealer and get a converter.

Apr 24, 2008 | Jenn-Air JDR8895AAS Dual Fuel (Electric...

1 Answer

Thermador PG484GGBS: How to convert from Natural Gas to LP?


I just did it with mine, I called thermador and they told me the number of the conversion kit to buy for my model.

I bought the kit from the retailer and did it myself, not very difficult.

no explosions yet :)
nic

Dec 25, 2007 | Thermador PG484GGEBS Stainless Steel...

Not finding what you are looking for?
Thermador PG484GGEBS Stainless Steel Kitchen Range Logo

382 people viewed this question

Ask a Question

Usually answered in minutes!

Top Thermador Kitchen Ranges Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

yadayada
yadayada

Level 3 Expert

76109 Answers

butch welch

Level 2 Expert

147 Answers

Are you a Thermador Kitchen Range Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...