In 2002, I had an Amana heat pump installed, in 2003, I had to have the defrost panel replaced and in April 2004, I had to have a new air handler installed, I'm not sure how many service calls I have had, but last year 2010, I had 3 calls at a cost of over $300, plus a new compressor, last week it ran and ran and did not heat my house at all. After several calls to the company they finally came and said the compressor was bad, it was replaced on Friday 4/8/2011, the weather was mild and I did not turn it on until yesterday when I needed air, the compressor ran just a little while and the blower is just blowing air. Friday's bill was over $300 for installation and freon. I am frustrated and ready to discuss this with my attorney. After online research I felt,Amana had the best waranty and service reviews. I am a widow and feel I have no recourse but to discuss this with my attorney. Maybe you can advise me otherwise. Sara Gardner

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 40 Answers

I would contact Goomman manufacturing directly and explain the problem.
remember tne product is only as good as the installer.
this should not be happening to you and i'am sure Goodman will help you
with this.

Posted on Apr 11, 2011

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Any problems with acura 2004 ?


According to repairpal: "Honda and Acura Recall Multiple Vehicles Due to Excessive Air Bag Inflator Pressure RepairPal Expert Overview: Honda has recalled 2001-2003 Civic, 2002-2003 Civic SI, 2001-2002 Accord, 2002 CR-V, 2002 Odyssey, 2003 Pilot, 2002-2003 Acura TL, and 2003 Acura CL vehicles because the driver's side air bag inflator may produce excessive internal pressure. This could cause the inflator to rupture if the air bag deploys. Metal fragments may pass through the air bag material and cause injury to vehicle occupants. Dealers will replace the driver's side air bag inflator.
Models: Acura CL, Acura TL, Honda Accord, Honda CR-V, Honda Civic, Honda Civic Si, Honda Odyssey, Honda Pilot Body, Interior & Misc., February 26, 2010 Honda Recalls 2001-2003 Vehicles Due to Excessive Air Bag Pressure RepairPal Expert Overview: Honda has recalled 2001-2002 Civic, Civic SI, and Accord vehicles and 2002-2003 Acura TL vehicles because the driver's side air bag inflator could produce excessive internal pressure. This may cause the inflator to rupture if the air bag deploys. Metal fragments may pass through the air bag material and cause injury to vehicle occupants. Dealers will replace the driver's side air bag inflator.
Models: Acura TL, Honda Accord, Honda Civic, Honda Civic Si Body, Interior & Misc., August 31, 2009 Acura Recalls 2004-2007 TL Models Due to Power Steering Hose Leaks RepairPal Expert Overview: Acura has recalled certain 2004-2007 TL models because the power steering hose may leak onto the extremely hot catalytic converter, which may cause a fire hazard. Dealers will replace the power steering hose with a new heat-resistant design.
Models: Acura TL Suspension & Steering, April 28, 2008 Acura Recalls 2004-2005 TL Vehicles Due to Corrosion in the Wiper Motor Housing RepairPal Expert Overview: Acura has recalled 2004-2005 TL vehicles because the wiper motor may stop working. Water may enter the wiper motor breather port and cause corrosion, which may cause the electrical circuit in the wiper motor to fail. Dealers will replace corroded wiper motors and modifications will be made to prevent water from entering the existing or new wiper motor.
Models: Acura TL Body, Interior & Misc., April 28, 2008 Honda Recalls 2005-2006 Models Due to Faulty Fuel Pump Relay RepairPal Expert Overview: Honda has recalled 2005 Accord, Odyssey, Acura RL, TL, TSX, and 2006 Ridgeline models because the fuel pump relay may fail. This can prevent the fuel pump from operating, which may cause the engine to stall or not start. Dealers will replace the fuel pump relay.
Models: Acura RL, Acura TL, Acura TSX, Honda Accord, Honda Accord Hybrid, Honda Odyssey, Honda Ridgeline Engine, April 2, 2007 Honda Recalls 2006-2007 Models Due to Incorrect NHTSA Contact Information in Owner's Manual RepairPal Expert Overview: Honda has recalled 2006 Accord, Civic, CR-V, Element, Insight, Odyssey, Pilot, Ridgeline, Acura MDX, RL, RSX, TL, TSX, and 2007 Honda Fit vehicles because the contact information for the National Highway Traffic Safety Administration (NHTSA) is listed incorrectly in the owner's manual. Honda is contacting dealers and customers to provide them with a postcard containing the correct information.
Models: Acura MDX, Acura RL, Acura RSX, Acura TL, Acura TSX, Honda Accord, Honda CR-V, Honda Civic, Honda Element, Honda Fit, Honda Insight, Honda Odyssey, Honda Pilot, Honda Ridgeline Body, Interior & Misc., August 2, 2006 Acura Recalls 2006 TL Vehicles Due to Loose Front Air Bag External I"mpact Sensor Bolts RepairPal Expert Overview: Acura has recalled 2006 TL vehicles because the bolts that mount the front air bag external impact sensors may be loose. If the sensor bolts fall out, the sensor may not function properly, which may prevent air bag deployment in the event of an accident. Dealers will inspect and re-torque the front air bag external impact sensor bolts.

May 07, 2015 | Health & Beauty

2 Answers

What is the problem with running a 10 SEER condenser with a 13 SEER air handler other than efficiency? I had a 2 ton 13 SEER air handler installed last August to replace one about 27 years old. The...


as most ac units are capillary tube control not tx valve having matched units is critical. as for cost the condensing unit is much more complex and expensive than the evaporator.

Feb 14, 2015 | Amana Goodman R-410A Heat Pump Condenser 2...

1 Answer

HE heat pump won't talk with old air handler?


The fact is, the air handler supplies the voltage, blower, and electric heat. In order for the heat pump to work correctly, the wiring from the thermostat and heat pump need to be hooked up right to the air handler. The thermostat is what tells which component to come on. If the fan stops, but the condenser keeps going, you either have a faulty fan relay on the air handler, faulty thermostat or wiring, faulty wiring at the heat pump, or the contacts on the new unit are sticking, which is highly doubtful considering it is working now. I hope I have helped you understand this a little more. Good luck and don't let them push you around, get someone that knows what they are looking at.

Jul 18, 2012 | Goodman Heating & Cooling

1 Answer

Amana heat pump/AEPF variable spd air handler system works great, but air flow at the higher speed is just too noisy (ducts are not very wide). Is there a way to limit how fast the air handler / blower...


Open the airhandler -should be a speed selector on the main board. If not -checkt he installation/set-up manual. May be some dip switches you can turn on or off to modify blower speed.

Jan 26, 2011 | Goodman CLQ36AR49 Air Conditioner

1 Answer

Where is the reset button on an Amana ASZ14 unit?


I don't think the Amana ASZ14 Heat Pump has a reset switch, but you can still reset it by resetting the power (when it's not running... turn your thermostat OFF first).

To reset the power, locate your circuit breaker box. There should be a double-breaker for the Heat Pump and another double-breaker for the Air Handler. Turn them both off for at least 2-3 minutes. Then flip them back on and turn your thermostat back ON.

You're thermostat may also have a RESET button that you can push. I have to reset mine every time I change the batteries in it.

Here are some more repair tips...

Heat Pump Troubleshooting & Repair:
http://www.hometips.com/repair-fix/heat-pump.html
Heat Pump Troubleshooting Repair

Amana ASZ14 web page:
http://www.amana-hac.com/products/heat-pumps/14-seer-asz14
ASZ14 Heat Pumps

Amana ASZ 14 SEER Technical Manual
(45-page PDF):
http://www.manualslib.com/manual/877256/Amana-Asz-14-Seer.html
Amana ASZ 14 SEER Technical Manual

Amana ASZ (and ASX) Service Instructions (66-page PDF):
http://www.acdirect.com/media/catalog/files/RS6200006.PDF

Jan 11, 2011 | Amana PTH123B25AJ Heat Pump Air...

1 Answer

New heat pump system freezing, questioning wiring.


W1 and E on stat need tied together. When W1 comes on wire where all heat elements come on. On the outside unit defrost board set the 45-60-90 to 45 and see if that takes care of the frost problem.

Jan 03, 2010 | Heating & Cooling

1 Answer

COMPRESSOR Amana / RCE24C2A Ser #036142440


mfg date are coded into the ser.# useualy fist 4 digits are yr and month of MFG. 0306 would be 2003 june ect. if in doubt call amanna dealer and ask them. Steve

Jul 12, 2009 | Heating & Cooling

1 Answer

Heat pump outside unit not running


It sounds like your defrost board failed. You will need a tech to replace it. With that model it may have a parts warranty but you pay labor(?)

Jan 18, 2009 | Amana PTH123B25AJ Heat Pump Air...

1 Answer

Will not go into defrost


Did you change the thermostat in heat pump? or did you change it when you replaced the board?

Dec 06, 2008 | Goodman CLQ36AR49 Air Conditioner

1 Answer

1997 Amana 2 or 2.5 ton heat pump, 13 seer - air handler only blows 4-5 min


do you have a totaline t-stat. they and some other brands have a fan recirculation setting in the installers menu.

this is assuming that this happens in addition to the heating or cooling normally

Jul 02, 2008 | Amana PTH123B25AJ Heat Pump Air...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

54 people viewed this question

Ask a Question

Usually answered in minutes!

Top Amana Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Bill Long

Level 3 Expert

587 Answers

Are you an Amana Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...