Duo therm air conditionning/furnace thermostat in RV

I can not turn on either the AC or the furnace. My model is the digital version with remote control.

Is it the control box in AC or the thermostat on the wall ?? Wiring is fine betwenn the 2 uints.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Dometic Master
  • 6,674 Answers

Checked all breakers & fuses in panel ?

Posted on Aug 14, 2008

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya Repairman can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repair professionals here in the US.
click here to Talk to a Repairman (only for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Compressor runs when power is off


If it is analogue selector switch, replace it or if it is in PCB model, repair it with an ac electronic technicians.

Sep 03, 2015 | Midea Westpointe, 12,000 BTU, Thru The...

1 Answer

Duo Therm 3109228.001


sounds like thermostat issue not communicating with relay modeule

Aug 01, 2014 | Dometic 3109228.001 Duo Therm Comfort...

1 Answer

I replaced the control box and thermostat but i have no power to the thermostat


I know this is an old question but almost all rooftop AC units get thermostat power from the Furnace. If you don't have good 12 volts at the furnace your thermostat will not work.

Jul 12, 2014 | Dometic Rooftop RV Air Conditioner

1 Answer

Weather kinf furnace ac system turn on at same time


possibly yes, also a faulty control board in your furnace can do the same. Need more details on heating type and model as well as which ac system is involved.

Jul 04, 2014 | Computers & Internet

1 Answer

Is there a youtube video replacing analog with lcddometic ctrl kit 3313189.000


Not that I am aware of but it is pretty straight forward. First, turn off the breaker to the AC. Then uplug the upper unit from the control box, Then disconnect the 110vac from the box, and then clip the thermostat wires. There will be, typically colored blue, two wires which go to your furnace, a ground wire and a 12vdc hot wire. The two blue wires will get the insulated female spade terminals installed so that they can be directly plugged into the new control box. The 110vac will wire into the new box the same as it was in the old box. The upper AC harness will plug directly into the new box and the new freeze control will plug directly into the new box and the yellow card will show you where to install it into the coils for the best results. You will receive a new harness that will supply power to the thermostat. Each wire is identified with a label and there is also a schematic on the inside lid of the new control box. Pick three wires from the thermostat wires and write down which one you assign to be neg, pos and comm. Wire the new harness with 12vdc + input to the 12vdc + supply. Wire the 12vdc - and the thermostat - to the 12vdc - supply. Wire the 12vdc + (Therm) to the wire that you have selected to be the positive wire to your thermostat and then connect the communication wire to the wire that you have selected to be the comm wire. Now, install the new thermostat on the wall with the three wires pulled through the small oval hole at the top. There will be three blue block terminals with small regular slotted screws in them. Each one is appropriately marked +, -, comm. Attach each wire that you have chosen accordingly. Once everything is wired in and secured turn the power back on and you should have a readout on the LCD display. You may have to hold the + and mode buttons until you get a - - which will program the thermostat for degrees Celsius. Now set the fan mode to AU and then adjust your cool temp. If you turn the furnace on in the winter time and the ac fan starts blowing go back to your fan setting and change it to AU. If it is set to LO or HI the AC fan will come on when the furnace is turned on. Have Fun!

May 18, 2014 | RVs

1 Answer

Duo therm ac in my rv quit when the converter burned up does the ac need 12v to work?


there is a fuse located under the shroud on the roof AC on a circuit board that controls the thermostat to turn on the power to the Air Conditioner replace it it is marked F-1 or, on some F-2 etc.
the air conditioner works on both DC voltage for the thermostat and AC voltage for the compressor

Sep 08, 2013 | Dometic 3312024.015 Duo Therm Comfort...

Not finding what you are looking for?
Dometic Rooftop RV Air Conditioner Logo

2,000 people viewed this question

Ask a Question

Usually answered in minutes!

Top Dometic Heating & Cooling Experts

Bill Long

Level 3 Expert

588 Answers

Donni Steen

Level 3 Expert

659 Answers

mike cooper

Level 3 Expert

884 Answers

Are you a Dometic Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...