1 Answer

Hi. I recently installed 1.5 T, 3 * Split AC, LG. Whole day the AC works fine and no problem in cooling too. But once in 2 day outdoor unit start making thudding noise continously and does not stop for 4 to 5 second and after that indoor unit stops cooling and just fan runs. No cooling is done after that and room temperature keep increasing. The green LED of compressor in indoor unit is ON, compressor does not work. To achieve cooling again I have to switch off whole unit for like half an hour and then switch it on, it works fine. But next day same problem. I am not able to figure out where is the problem.

Posted by on

  • Vijay Jadav Apr 09, 2011

    Thanks for the reply. I think the first reason you gave seems right to me. I might have a proper voltage supply problem. Previously it used to occur once in a day but now it happens, everytime I switch ON AC. After every 5 to 6 minutes, it makes some noise and compressor goes OFF.

×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Genius:

    An expert who has answered 1,000 questions.

  • Master
  • 1,400 Answers

Hello

Sounds like the compressor is shuting down on high heat.There could be a couple reasons for this.
1 Check that proper voltage is being supplied to compressor.
2 Freon level may be low.This would be a service call.
3 Bad or intermitent connection at thermostat.
4 Main contacts to compressor sticking,usually burnt or pitted.

Posted on Apr 08, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

36VDC Indoor split in a 240VAC country


if you use the correct inverter and transformers
best if you just get new units designed to run in that country

Jun 23, 2017 | Heating & Cooling

1 Answer

SPLIT AC CONDENSER TRIPS AFTER 1 OR 2 MINS, ONLY DURING THE DAY TIME


The condensor is not cooling fast enough. Try cleaning the condensor coil. Also check that the fan goes on. At night the outside temperature is cooler and does not need much work to cool down the condensor.

Jul 15, 2012 | Haier Heating & Cooling

2 Answers

Split AC whole unit turnig off at each compressor start up!


Dirty coil wash outside unit with water and change indoor unit filter

Jun 08, 2017 | Heating & Cooling

1 Answer

MY LG SPLIT A.C 1.5T ONES HAVING EXCISSIVE SOUND ON OUTDOOR UNIT Purcheses on may 2011.


hi,
The bearing of the outdoor fan have some problem that's why it makes noise. Try to put some oil on the shaft of the fan. if then also the sound remains you have to replace the bearing or the fan as a whole.
ok

Jun 09, 2011 | LG LS-L1210CL Mini Split Air Conditioner

1 Answer

My samsung split ac is not cooling. there is air blowing no cool air .before the roomwill get cooled within 30 minutes.


could have leaked out all its gas. if its an older unit it may be cheaper and easier to replace the whole unit. will make a buzz noise occasionaly from the outdoor unit. this is the compressor tring to pump the gas that is not there. check if the fan on the outdoor unit turns on.

Apr 03, 2011 | Heating & Cooling

1 Answer

Installed LG split system. The unit does not


Any chance that you've got L1 and L2 hooked up to the same leg of the main? That would still give you 120 on each but not 240 from L1 to L2 like it should be. I'm not familiar with the LG system, but I would think that a comm line would have two wires.

Jul 14, 2010 | LG Art Cool LA181CNW Split System Air...

1 Answer

My Outdoor unit not starting ... but indoor is running fine


check the capacitor. it might be defective, i would have a certified electrician or hvac tech trouble shoot it..if you never had worked on a/c b4...........you could probably ruin it more....................if you dont know what your doing......

Apr 16, 2010 | Samsung AS18A6RB Air Conditioner

1 Answer

Air Conditioner compressor not turning on


Check the following:

* The outdoor condesner coil to make sure it's clean

* The outdoor condenseing unit to make sure the fan runs

* The circuit breaker for the A/C condenser and any other circuit protection , if present

* The regrigerant charge

* Wiring connections

* The thermostat setting (make sure it's calling for cooling)

Jun 06, 2009 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

246 people viewed this question

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Donni Steen

Level 3 Expert

659 Answers

Tim Whalen

Level 3 Expert

3072 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...