Question about Office Equipment & Supplies

1 Answer

Page Pro 9100 Fuser low temp status 19 - Office Equipment & Supplies

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Contributor
  • 185 Answers

This is probably a bad fuser (rarely does anything else cause it) <div><br /></div> <div>PN 1710501-001</div> <div><br /></div> <div>It's not too hard to install. Just remove 4 screws and remove/ replace. <br /><br />Whit<br />Item, Inc. <br /> <div><br /></div> <div><br /></div></div>

Posted on Aug 23, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

E studio 520 code c447


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0." also 447

Jan 17, 2014 | Toshiba Office Equipment & Supplies

1 Answer

Error code c43


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."

Jan 14, 2014 | Toshiba Office Equipment & Supplies

1 Answer

Call for service C 430


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."

Dec 31, 2013 | Toshiba estudio 255 Copier

1 Answer

TOSHIBA E STUDIO 207 ERROR C 44


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."

Jul 08, 2012 | Toshiba E Studio 207

1 Answer

Will not print under OSX 10.7


QMS is a legacy company under then Minolta, now Konica Minolta I believe page pro 9100 is very old I believe that it would work with windows 95 or xp at best.

Nov 13, 2011 | Minolta QMS PagePro 9100 Laser Printer

1 Answer

My kyocera photocopying machine is asking me to callservice 6000 what can i do/ what does it mean?


6000 simply means Broken fuser heater lamp wire
The temperature does not reach 100°C/212°F after the fuser heater lamp has been turned on continuously for 30 s. The temperature does not rise by 1°C/1.8°F after the fuser heater lamp has been turned on continuously for 5 s during printing. 35/37 and 45/47 ppm printers (EUR/USAmodel):
Fuser thermistor M detection temperature does not rise by 1°C/1.8°F
after the fuser heater lamp has been turned on continuously for 10 s during warm-up or at standby.Fuser thermistor S detection
temperature does not rise by 1°C/1.8°F after the fuser heater lamp has been turned on continuously for 5 s during warm-up or at standby.
Poor contact in the fuser thermistor M connector terminals.Reinsert the connector (See page P.1-5-19).Fuser thermistor M installed incorrectly.
Check and reinstall if necessary (See page P.1-5-19).Thermal cutout
triggered.Check for continuity. If none, replace the thermal cutout (See page P.1-5-19). Fuser heater lamp installed incorrectly. Check and reinstall if necessary (See page P.1-5-19).Broken fuser heater lamp wire. Check for continuity. If none, replace the fuser heater lamp (See page P.1-5-15).

Oct 26, 2009 | Kyocera FS-1118MFP Laser Printer

2 Answers

HP4345 MFP printer and the print quality is fuzzy. I put in a new toner cartridge and that didn't work and i also created a cleaning page and that didn't help. what next? just had the tech out here last...


Fuzzy print is mostly related to 3 items in your printer. 1 the toner cart. 2 fuser. 3 transfer roller. A fuser replacement is a normal fix for this problem. Check your PM kit status by printing a supplies status page. A PM kit will have a fuser, transfer roller and feed rollers. If the PM level is low ,order and replace kit. If not you may want to get a new fuser

Sep 23, 2009 | HP LaserJet 4345mfp Printer

2 Answers

Call service 6000:0098269


6000 Broken fuser heater lamp wire
The temperature does not reach 100°C/
212°F after the fuser heater lamp has
been turned on continuously for 30 s.
30/31 ppm printer (EUR/USA model):
The temperature does not rise by 1°C/
1.8°F after the fuser heater lamp has
been turned on continuously for 5 s during
printing.
35/37 and 45/47 ppm printers (EUR/USA
model):
Fuser thermistor M detection
temperature does not rise by 1°C/1.8°F
after the fuser heater lamp has been
turned on continuously for 10 s during
warm-up or at standby.
Fuser thermistor S detection
temperature does not rise by 1°C/1.8°F
after the fuser heater lamp has been
turned on continuously for 5 s during
warm-up or at standby.
The temperature does not rise by 1°C/
1.8°F after the fuser heater lamp has
been turned on continuously for 5 s during
printing.
Poor contact in the
fuser thermistor M
connector terminals.
Reinsert the connector (See page P.1-5-19).
Fuser thermistor M
installed incorrectly.
Check and reinstall if necessary (See page
P.1-5-19).
Thermal cutout
triggered.
Check for continuity. If none, replace the
thermal cutout (See page P.1-5-19).
Fuser heater lamp
installed incorrectly.
Check and reinstall if necessary (See page
P.1-5-19).
Broken fuser
heater lamp wire.
Check for continuity. If none, replace the
fuser heater lamp (See page P.1-5-15).

Sep 02, 2008 | Kyocera FS-3900DN Laser Printer

1 Answer

Canon copier error message "error001"


"E000" Low fuser temp. (Heat lamp, thermoswitch, thermistor, SSR) "E001" High fuser temp. (Thermistor) "E002" Fuser temp. too low "E003" Fuser temp. too low "E004" SSR, Fuser temp too highchange thermistor in fuser

Aug 27, 2008 | Office Equipment & Supplies

Not finding what you are looking for?
Office Equipment & Supplies Logo

Related Topics:

76 people viewed this question

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

kakima

Level 3 Expert

102366 Answers

k24674

Level 3 Expert

7993 Answers

yadayada
yadayada

Level 3 Expert

69199 Answers

Are you an Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...