Question about Heating & Cooling

Open Question

Brivis wombat 92 central duct heating,pilot is on,fan constantly blows air out no heat at all just air,test button red light is on and buzzing noise. Please help.

Posted by on

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 2 Answers

SOURCE: Air blowing out - Pilot on but no heat.

Possibly overheating or previously overheated, these units are also prone to control box issues usually a buzzing noise at the unit it present if this is the case.

Posted on Apr 28, 2010

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a brivis buffalo 85 ducted heating system, from last few days it doesn't come hot air only fan is running. pilot lamp also not with flame. ignation is working. I was turm blue color lid to pilot...


you need a new thermocouple. u can either get one from a plumbing store but the can be a bit fiddley to fit or u can get the proper Brivis one it just pulls out and u put the new one in. then u have to re light the pilot light. make sure u hold it down for at least 45 sec to make sure that it is getting hot enough when u release it it will stay alight then turn gas valve to the on position

May 26, 2014 | Heating & Cooling

1 Answer

Brivis wombat 2P 20


love to know how you went , i have a similar problem with the same unit.....

May 29, 2013 | Heating & Cooling

1 Answer

Pilot light is large and yellow on the brivis 92 wombat


blocked pilot , lack of air so it burns yellow needs blowing out with air line or can of air , or undo and clean pilot .

Jul 25, 2011 | Heating & Cooling

1 Answer

My brivis wombat 120 igniter won't work so I can't light the pilot


I have a brivis wombat 120. When room temperature is lower than required temperature, it starts to fire up and sends heating air. Now, it does start firing. If I increase the temperature testing, you can hear ant click sound from heater, but no firing. Can anyone help

Mar 26, 2011 | Heating & Cooling

1 Answer

Burners on our Brivis Buffalo 52 Ducted heater aren't getting gas


test thermosat for proper operation ie-broken wire-power if good jump stat and check if unit goes on if it does than stat internal problem or wiring problem and needs replacement or repair --if stat good check fan safety/high limit sensor if good would need to check and test thermocouple thats the tube that the pilot flame burns on may be enough to keep pilot burning but not enough to open valve for heat demand

May 31, 2010 | Heating & Cooling

1 Answer

Brivis Upflow/Downflow fan on continuously, no heat


depending on the year of the unit

if its between 1992-1999 it would be caused by the either the pilot not staying alight, or a faulty gas valve not opening,
These models start the fan on a time delay not tempreture so you will only get cold air circulating and when the thermostat is off the fan will stop.
(All models) if the fan is running regardless of the thermostat position an over heat sensor is faulty.

May 17, 2010 | Heating & Cooling

1 Answer

Air blowing out - Pilot on but no heat.


Possibly overheating or previously overheated, these units are also prone to control box issues usually a buzzing noise at the unit it present if this is the case.

Apr 28, 2010 | Heating & Cooling

1 Answer

Brivis Buffalo 85 ducted heating unit, fan is always on


On the unit outside there is a button that says "push man. pull auto" if it is set to push man then the fan will go constantly.

Sep 22, 2009 | Heating & Cooling

4 Answers

Brivis central heating fan will not switch off runs continuous


brivis wombat 2P 20 ducted heater, gas fires up but fan not starting
Any suggestions...???

May 12, 2009 | Heating & Cooling

1 Answer

Heating isn't working, can't find the red button to relight the pilot


Many times the knob to turn the gas on on the valve is also the pilot knob. Turn it to pilot and hold it down while you light the pilot. Hold it for up to a minute and release. If the pilot stays on then turn it to on. If not you need a new thermocouple.

Apr 26, 2009 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

199 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2517 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...